AXIS Q1602-E/AXIS Q1604-E Installation Guide
Function
Pin
GND
1
3.3 V DC
2
Power
Digital
3
Input
Digital
4
Output
Note:
See the User Manual for more information.
LED indicators on camera
LED
Color
Network
Green
Amber
Unlit
Status
Green
Amber
Red
Power
Green
Amber
Notes
Ground
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
Connect to GND to activate, or leave floating
(unconnected) to deactivate.
Note: Connected to housing at delivery.
Internal connection to ground when activated,
floating (unconnected) when deactivated. If used
with an inductive load, eg. a relay, a diode must
be connected in parallel with the load, for pro-
tection against voltage transients.
Indication
Steady for connection to a 100 Mbit/s network. Flashes for network activity.
Steady for connection to 10 Mbit/s network. Flashes for network activity.
No network connection.
Steady green for normal operation.
Note: The Status LED can be configured to be unlit during normal operation, or to
flash only when the camera is accessed. To configure, go to Setup > System
Options > LED settings. See the online help files for more information.
Steady during startup, during reset to factory default or when restoring settings.
Slow flash for failed upgrade.
Normal operation.
Flashes green/amber during firmware upgrade.
Page 21
Specifications
Max load = 50 mA
0 to +40 V DC
Max. load =100 mA
Max. voltage = + 40 V DC