Herunterladen Inhalt Inhalt Diese Seite drucken

Axis Q1602-E Installationsanleitung Seite 10

Vorschau ausblenden Andere Handbücher für Q1602-E:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 48
Page 10
Connect the cables
1. Optionally connect external input/output devices. See
2. Connect the network cable to the network connector in the housing.
Note: A shielded network cable (STP) must be used to protect the product against power surges.
3. Check that the status LED on the housing indicates the correct conditions. See the table on
page 22 for further details.
Cold Start-up Delay Switch
This switch is enabled by default; ensure it remains on.
The housing used in this Axis product features Arctic Temperature Control, which is enabled by
setting the Cold Start-up Delay switch to I (ON). When enabled, this function controls when the
camera restarts after a power cut, when temperatures are below 0 °C (32 °F); the camera is first
heated to approximately 0 °C (32 °F) before it initializes. This prevents damage to camera parts that
are sensitive to sub-zero temperatures.
Attach top cover
1. Attach the top cover to the bottom cover. Make sure to tighten diagonally opposite bottom
cover screws a few turns at a time until all are tight. Do not tighten screws completely the first
time.
2. Loosen the sunshield adjustment screws and adjust the sunshield to the desired position.
AXIS Q1602-E/AXIS Q1604-E Installation Guide
I/O terminal connector,
Network connector (PoE OUT,
connected at delivery)
Cable holes
Network connector (PoE IN)
LED indicator
Cold Start-up Delay switch
Alarm output
(connected at delivery)
on page 20.
Network cable
I/O cable
Bottom cover

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Q1604-e

Inhaltsverzeichnis