Installation
WARNING: wrong installation can cause
injuries.
The control type T100 R is intended for
!
operation on gates with vertical and
horizontal movement.
0
Required tools
1
Installing the control unit
2
Opening the control unit cover
Turn off the main switch or pull the mains
plug before opening the top control cover.
Wait 1 minute to let any residual voltage at
the motor terminal die down. Protect
against unauthorized starting.
3
Connections
Designation:
J1
Impulse inputs
J2
Safety photocell, two or four-wire or light
array
J3
Closing edge OSE / 8K2 / DW
J4
Emergency-STOP, slack cable, latching
J5
Unassigned
J6
Anti-crash detector
J7
Key switch
J8
Timer inputs
J9
Digital limit switch - motor cable
J10
Connection of add-on controls
J11
Connection of radio receiver
J12
Aerial
J13
Membrane keypad
X1
Mains connection
X2
Mains output L, N (500W / 230V)
X3
Protective conductor contact
X4a
Magnetic brake
X5
Floating relay contact 1,
door status relay
X6
Floating relay contact 2,
door status relay
X7
Door operator
X8a
Light array transmitter output
X8b
24V DC, max. 700mA
4
Mains connection
The control is ready for connection by CEE-Cara 16A
plug and approx. 1m cable as shown in 4a.
The unit must be connected to the mains in
!
accordance with the existing power supply
voltage. The customer should provide a 10-
amp fused automatic circuit breaker for the
control.
5
Motor connecting lead
The connecting lead for the motor and digital limit
switch DES is pre assembled and ready to use
(
)
-
attach accordingly. X4 - magnetic brake connection.
6
Impulse generator connection
The gate must remain visible from
the place of operating it.
6a/6b - Connection J1 for external control units
Open, Stop and Close.
6c - Switching sequence Open-Stop-Close, set
value 4 in menu 51.
J1.3 - door half open, J1.4 – door fully open
6d - Open-Stop-Close with lighting
7
Timer inputs
Terminal J8 is intended for operating devices, for AR
service, same as push-pull switch
loops
7b
and motion detector
7c.
automatically at the end of the time set in menu 44.
The open time by the light barrier can be set to a
shorter time in menu 38.
8
Front area monitoring
If the closing speed is greater than 50 cm / s
than must the entire door width and depth
of 90 cm are monitored on both sides of the
door.
Connection diagram 8 shows the run-up monitoring
by motion and present detectors Condor.
9
Safety edge connection
Door connection socket with slack rope switch or
break-away sensor and slip door contact 8.
Select the setting of the safety edge connection in
menu 35:
Door connection socket with slack rope switch and
slip door contact 8.
- Optical closing edge OSE - only OSE from Fraba or
Witt are permitted
- Electrical safety edge 8K2 with a termination
resistor of 8.2 kOhm (value = 1)
- Electrical safety edge 8K2 in series connection with
slack rope and wicket door switch (value = 3)
- Pressure wave edge and switch with a loop
resistance of 8.2 kOhm (value = 2)
10
Connection for light array
The following light arrays can be connected.
10a
Light array with testing
For this, set value 5 in menu 36.
10b
Light array with OSE interface
For this, set value 0 in menu 36.
10c
light curtains with OSE interface
CEDES GridScan/mini-SB-2
35 menu, you must set the value 0 for it.
10 d
light curtains with OSE interface WITT
LIGI A value of 0 must be set for the
menu 35
11
Photocell connection
11a Two-wire photocell Ls2
11b Four-wire photocell LS5 with self-testing
11c Reflection photocell
If in the menu the frame-fitted photocell has been
selected, the next time the door closes the control
unit automatically initiates a learning run to detect
the position. E10 will be disdplayed.
During this process the closing procedure
must not be interfered with, otherwise the
wrong position could be recorded.
12
Anti-crash sensor
Input J6 detects when the curtain is off guide and
starts an automatic threading up.
One-way light barrier with relay output
transistor output 1 b.
-
13
Emergency-STOP connection
Use input also for spring break switch.
14
Key switch / pull button connection
When using a key switch / pull button, the desired
function in menu 50 should be selected.
15
Radio remote control
Slip receiver module (optional) on J11 and connect
the antenna. Program the handheld transmitter.
16
Relay output
2 change-over contacts:
max. 250VAC / 2A or 24VDC / 1A.
24V-output X8: max. 700mA
Selecting the relay function in menu 45 and 46.
7a,
induction
15c Interlocking of two doors (lock circuit).
The door closes
Menu 50 value 2 and menu 46 value 1.
15c I
nterlocking of
Menu 50 value 2 and menu 46 value 1.
.
1 a,
2
with
2
three
doors (lock circuit).

Programming the control unit

The programming is menu-driven. Carry out
adjustment of the door in accordance with the
scheme. The following page shows the full extent of
the menu.
Set the correct motor and brake type before
!
setting the end positions (menus 78 and 79).
Wrong setting can damage the door.
No door type selected: E01 is displayed.
Brake selection (menu 78)
Brake type A, currentless braking, is applied at the
same time (value=0) or with a delay (1-9) after stop of
the motor.
Brake type B, currentless opening, opens at the
same time (value=10) or with a delay (11-19) after
stop of the motor.
Setting the door end-of-travel positions (menus
30 and 31)
The top and bottom end positions should be set
directly one after the other.
Gate run optimization
For smooth gate run, set soft start in menus 70 and
72 and soft start for attaining end position in menu
71.
Correcting the slowing-down path (menu 42)
Compensates changes in the closed position
resulting from temperature fluctuations, gearbox
run-in etc.
Level adjustment (menu 43)
Compensates changes in the closed position
resulting from cable elongation or a rise in the floor
level. The Closed end position is adapted by ground
contact of the closing edge guard.
Set the precise closed position beforehand, then set
in menu 43.
The positions taught in menus 31, 34 and 37 are
adapted accordingly in settings 2, 3 and 4.
Soft start and soft stop
To optimize smooth run and running behavior, the
settings in menus 70, 71 and 72 can be changed.
ON period (menu 49)
The ON period set will prevent the drive motor from
getting overheated and thus getting damaged.
RWA (smoke-heat exhaust) function
Set the required door position in menu 55. Connect
fire alarm to J7 and set value 9 in menu 50.
Programming the radio remote control
Please note that each hand transmitter must be
individually programmed. It is possible for up to 30
radio codes to be learned. The following functions
can be taught in.
KeeLoq, 12 Bit Multibit. The first code determines the
type.
Start impulse (menu 60)
Enter the menu and press the button on the hand
transmitter for the START function. As soon as the
code has been learned, the incremental display
flashes five times.
Half-open position of the door (menu 61)
Enter the menu and press the button on the hand
transmitter for the half-open position. As soon as the
code has been learned, the incremental display
flashes five times.
Light function (menu 62)
Enter the menu and press the button on the hand
transmitter for the light function. As soon as the code
has been learned, the incremental display flashes
five times.
Deleting radio codes (menu 63)
To delete all the learned codes in the menu, press the
oval button and keep it pressed for 5 seconds.
Selection of the transmitter mode (menu 64)
In addition, the transmitters taught in this menu can
temporarily be blocked in this menu.
GB