5 Troubleshooting

Problem
No sound.
Distortion.
Microphone sound be-
comes duller
by and by.
20
Possible Cause
1. Power to mixer
and/or amplifier is off.
2. Channel or master
fader on mixer, or vol-
ume control on ampli-
fier is at zero.
3. Microphone is not
connected to mixer or
amplifier.
4. Cable connectors are
seated loosely.
5. Cable is defective.
6. No supply voltage.
1. Gain control on mixer
or transmitter module
not set correctly.
2. Mixer input sensitivity
too high.
Internal or external
windscreen attenu-
ates high frequencies
when soiled.
Remedy
1. Switch power to
mixer or amplifier on.
2. Set channel or master
fader on mixer or vol-
ume control on ampli-
fier to desired level.
3. Connect microphone
to mixer or amplifier.
4. Check cable connec-
tors for secure seat.
5. Check cable and re-
place if damaged.
6. Switch phantom
power on.
Check cable and re-
place if necessary.
1. Set gain control to
stop distortion.
2. Insert 10 dB preatten-
uation pad between
microphone cable
and input.
Clean internal or ex-
ternal windscreen.