Programmieren
At power-up, select the
preferred language.
Select language
[1] English
Setup 1
Status
Quick
Menu
Menu
Com.
OK
On
Warn.
Alarm
O
Hand
Reset
On
Power-up Screen
OK
The next screen is
the Wizard screen.
Press OK to start Wizard
Press Back to skip it
Setup 1
Status
Quick
Menu
Menu
Com.
OK
On
Warn.
Alarm
O
Hand
Reset
On
Wizard Screen
if
0.0 Hz
0.0 kW
Setup 1
Status
Quick
Menu
Menu
Com.
OK
On
Warn.
Alarm
O
Hand
Reset
On
Status Screen
The Wizard can always be
reentered via the Quick Menu
Wizard completed
Press OK to accept
0.0 Hz
0.0 kW
Abbildung 4.4 Inbetriebnahmeassistent für Anwendungen ohne Rückführung
Parameter 1-46 Verstärkung Positionserkennung und Parameter 1-70 PM-Startfunktion sind ab Softwareversion 2.80 verfügbar.
MG18A803
Kurzanleitung
... the Wizard starts
PM motor
Motor current
Main
3.8
Menu
A
Motor nominal speed
3000
RPM
Motor Cont. Rated Torque
5.4
Nm
Stator resistance
0.65
Ohms
Auto
On
Motor poles
8
Motor type = IPM
Back EMF at 1000 rpm
57
V
Motor type = SPM
Main
if
OK
Menu
Auto
On
Main
Menu
Motor type = PM motor
Auto
On
Current
Set T53 Low Current
04.66
A
Set T53 High Current
13.30
A
(Do not AMA)
Auto Motor Adapt OK
Press OK
AMA OK
Danfoss A/S © 05/2016 Alle Rechte vorbehalten.
Select Regional Settings
[0]
Power kW/50 Hz
Grid Type
[0]
200-240V/50Hz/Delta
Motor Type
Asynchronous motor
Asynchronous
[0]
Motor Power
1.10
Motor Voltage
400
Motor Frequency
50
Motor Current
4.66
Motor nominal speed
1420
IPM type = Sat.
q-axis Inductance (Lq)
d-axis Inductance Sat. (LdSat)
5
5
mH
mH
q-axis Inductance Sat. (LqSat)
5
mH
IPM Type = non-sat.
Current at Min Inductance for d-axis
100
Current at Min Inductance for q-axis
100
PM Start Mode
[0]
Rotor Detection
Position Detection Gain
100
%
Locked Rotor Detection
[0]
O
Locked Rotor Detection Time[s]
0.10
s
Max Output Frequency
65
Hz
Motor Cable Length
50
m
Set Motor Speed low Limit
0000
Hz
Set Motor Speed high Limit
0050
Hz
Set Ramp 1 ramp-up time
0010
s
Set Ramp 1 ramp-down Time
Motor type = Asynchronous
0010
s
Active Flying start?
[0]
Disable
Voltage
Select T53 Mode
[0]
Current
Set T53 low Voltage
0050
V
Set T53 high Voltage
0220
V
Set Min Reference
0000
Hz
Set Max Reference
0050
Hz
Select Function of Relay 1
[0]
[0] No function
Select Function of Relay 2
[0]
No function
Automatic Motor Adaption
[0]
O
Do AMA
AMA Failed
AMA running
-----
AMA Failed
kW
V
Hz
A
RPM
%
%
4
4
27