OPEN WINDOW DETECTION
This function makes it possible to detect an open window and automatically activate the Anti-freeze operating mode.
When the function is enabled and ready to set the Frost-free mode if an open windows is detected, a dedicated icon
lights up on the lower area of the display.
If a temperature drop is observed in the room during the normal functioning, the Frost-free mode is automatically acti-
vated to save enery consumption. The icon flashes to show that the open window function operates.
The reset of the normal functioning is not automatic but is achieved by pressing one of the six buttons of the product.
- Correct operation of this function may depend on where the radiator is positioned in the room, the presence
of draughts, the outside temperature, and how long the window stays open.
- The open window detection function can be used only in Comfort, Eco and Pilot wire mode.
DISPLAY / CHANGE THE COMFORT TEMPERATURE
You can check the set Comfort temperature at any time by pressing a single time the
is in Comfort, Pilot wire o Programmed mode. A further pression will modify the set temperature.
Note: The temperature measured by the inner sensor of the product is representative of the ambient temperature
nearby it and it may differ from the temperature measured using other instruments in other areas of the room. That
difference may depend on many factors including, for example:
- the installation position: some areas of the room may be affected by drafts or hot air sacs that modify the sensor
measurement;
- the fixation to an external wall that, being normally colder than internal walls, may imply the measurement of a tem-
perature lower than the real room temperature;
- a full load of towels on the support bar may obstruct the airflow. As a result the sensor may measure a temperature
higher than the real room temperature;
- unstable conditions: any evaluation must be done in stable working conditions. For this purpose comfort temperature
should be changed only 60min after a previous change . It is not possible, indeed, to evaluate the room temperature
maintained by the product correctly if the comfort level temperature is continually changed in a short time.
If a difference between set temperature and room temperature is detected in stable working conditions, measure the
difference and then increase or decrease the comfort temperature on the product of the exact value of measured
difference.

AUTOMATIC MODE

Pushing the button
makes it possible to activate the following automatic operating modes in sequence:
Comfort
The product automatically selects the power required to reach and maintain the Comfort temperature set by the
user. The
symbol switches on at the top of the display.
Eco
The product automatically selects the power necessary to reach and maintain the Eco temperature, which is
equal to the Comfort temperature -3,5°C. The
Anti-freeze
The product automatically selects the power necessary to reach and maintain the anti-freeze temperature, which
is equal to 7 + 3°C. The
Towel warmer
The product activates heating, NOT regulated by the thermostat, of the front surface, for heating / drying towels.
The operating time is fixed, not editable, and set at 60 min. On completion of this operation, the product goes into
Stand-by mode. While operating, the
shown in place of the current time.
Pilot wire
In this mode, the product operates according to the signals received by a pilot wire control unit (not supplied).
The
symbol switches on at the top of the display