2. Wall mounting

Only fix the heater in vertical position with the air outlet grid downward;
This heater is fitted with a double electrical insulation circuit (class II) and therefore does not require an earth
connection.
This heater must be correctly installed in compliance with the regulations in force in the country of installation.
In wet spaces like bathrooms or kitchens, the connection terminal must be installed at least 25 cm above the
floor. The electrical connection to the power supply must also be fitted with a two-pole switch with a minimum
gap between the contacts that allows complete disconnection according to excess voltage III category conditions.
Always make observe the minimum distances from walls, furniture and/or objects, as indicated in picture 2. Never
install the product so that the distance between the floor and the lower side of the product is less than 600 mm:
-
Drill four 6mm diameter holes in the wall, as shown in picture 3;
-
Insert the four wall plugs supplied with the product;
-
Fix the wall bracket with the 4 screws as shown in picture 4.
To fix one or both the towel rails to the product, before hanging it to the wall bracket, proceed as follows:
-
Insert at the extremity of the towel rails the M6 x 12mm screw and fix to it the T-nut as shown in picture 5-A;
-
T-nut must be just slightly screwed and not tighten to the end so that it will enter inside the profile of the
towel warmer (picture 5-B);
-
Slide the towel rail from the top being careful not to scratch the glass or the mirror (picture 5-C);
-
Slide the towel rail until the desired positin is reached (picture 5-D);
-
Move the towel rail towards the front of the heater untill the T-nuts previously fixed enter the lateral profiles
of the product (picture 6-A/B);
-
Fully tighten the screws at the extremity of the rail until the T-nut rotates and locks inside the profile (picture
6-C).
To fix the product to the wall, after the towel rails have been fixed:
-
Hang the product to the upper hooks of the wall bracket (picture 7-A/B);
-
Rotate the lower part of the product towards the wall untill the 2 side spring hooks snap in position inside
the back panel of the heater (picture 7-C).
3. Filter
This product is fitted with a filter to protect the heating element from dust and dirt.
The filter is removable to be easily cleaned with water (picture 8-A/B).
To keep the heater in perfect condition, clean the filter once every six months REMEMBERING TO PUT IT BACK
AGAIN AFTERWARDS (picture 8-C).
Every 120 working hours, the user is notified of the need to clean the filter on the back of the product. The warning
is given by the flasing of the
Even when the display is showing the message indicated above, the product continues to work in the mode active
at the time the notification appears.
If
or
key is pushed the text is removed from the display leaving the warning icon
again be displayed when the fan heater has been running for another hour.
By holding the
key down when the notification is displayed, the built-in counter is reset and the notification
will be displayed again after another 120 working hours. Confirmation of resetting is given by a message on the
display for 5 seconds that reads "donE " .
4. Towels
Always place the towels well stretched over the rails (picture 9-A);
Do not roll the towels between the rails and the glass (picture 9-B);
Do not cover the product with the towels (picture 9-C) and do not place the towels in any other way that is not
the provided one.
Feel good through warmth from electricity - www.technotherm.de
icon and a running message on the display that reads:
" PULIRE FILTRO - CLEAN FILTER - NEttOYER FILtRE " .
on. The text will once

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis