Herunterladen Inhalt Inhalt Diese Seite drucken

Operation; Maintenance - Aerfast CRT4 Anleitung

Pneumatische hefter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

• Before plugging-in the device:
 Check for compressor and piping capacities;
 The flexible pipe should not be too long (rubber pipe 3 to 4 m max.);
 Check that equipment filter, lubricator and pressure regulator are working properly;
Oil for lubricator: 3-5 drops / Nm
 225g
code 78629
 900g
code 78630
 3.8L
code 78631
• Fill the loader:
 Load a staples strip, on the slider with the staple-pusher in the forward position;
 Pull the staples pusher backward until it arrives behind the staples strip;
 Gently release until contact with staples;
 Plug-in air supply, the tool is ready to use.
VERY IMPORTANT - EVERY DAY:
Evacuate all dust, glue and staple fragments inside jaws and staples loader.
VERY IMPORTANT - Every 50000 CYCLES:
(see exploded views for oil/grease references)
Lubricate mechanical parts after cleaning them.
Oil the valve part and the piston part.
Ensure of right status and well tightening of parts.
CAUTION!
Before disassembly, always disconnect air supply!
When reassembling the device, lubricate the moving parts and oil seals.
When reassembling the device, put Loctite
to vibration.
Use staples from the manufacturer.
CRT4 (ind. D) – 31/08/2018

OPERATION

3

MAINTENANCE

243 on all nuts and bolts so as to avoid loosening due
®
12