REMOTE connectors
The REMOTE connectors 1 to 4 allow you to control, from a WPm series wall panel or similar (0-
10VDC), the volume of one or several inputs, or the volume of one or several outputs simultaneously, to
select presets, sources for one or several zones and control the volume sent to these zones etc. The
inputs or outputs controlled by each REMOTE port are selected using either the device setup menu
(front keys and LCD display) or EclerCOMM Manager application software (see chapter 9 for more
information).
The WPm series wall panels must be configured with their internal jumpers in 10V / LIN position.
MUTE connector
The rear panel MUTE connector allows the connection of an external potential free contact
closure to mute one or several output zones of the device, when an external unit is activating it
(example: a central alarm system for emergencies and evacuation). The MUTE port affects the outputs
selected from the device setup menu (front keys and LCD display) or from EclerCOMM Manager
application software (see chapter 9 for more information).
RS-232 port
The RS-232 serial communication port allows remote management of DAM614 from a computer
or external control system supporting theCA-NET protocol, or from the free EclerCOMM Manager
application software.
See the manual of the CA-NET protocol for complete information about the details of the
connection and the syntax of supported commands.
The specifications of the DAM614 serial connection are
o Baud rate: 9600 (Fixed, without auto-negotiation)
o Data bits: 8
o Parity: None
o Stop bits: 1
o Flow control: None
o Cable: standard RS-232 type, DB9-DB9 (pin-to-pin)