9.2.1. UP – User settings
Description
UP01 restart mode power failure
[rA = automatic; rM = manual]
UP02 Nominal pump current
UP03 Nominal pump frequency
UP04 Direction of rotation
[ --- = std rotation; --- = inverted rotation]
UP05 Set point pressure
9.2.2. AP – Advanced settings
To enter password is required (see paragraph 10.1.)
Description
AP01
Pressure transducer set-up
[sensor full-scale]
AP02
Ramp down
AP03
Ramp-up
(fixed value for MM)
AP04
Time before stop
AP05
Dry-run time
AP06
First dry-run time
AP07
Dry-run pressure
AP08
System dynamic
[1 = fast dynamic; 5 = slow dynamic]
AP09
Cascade mode
[oFF; UU = cascade mode with double inverter;
dP = Twin pump
UF = cascade mode with an inverter]
AP10
Master/Slave setting
MAS = master; SLA = slave
AP11
Reset to factory set-up
AP12
Digital input activation
[0 = oFF; 1 = no; 2 = nC]
AP13
Digital output activation
[0 = oFF; 1 = on; 2 = no; 3 = nC]
AP14
Restart fall pressure set-up
AP15
Pump address
AP16
Cascade mode start fall pressure set-up (bar)
AP17
Cascade mode restart delay
AP18
Cascade mode fall pressure limit set-up (bar)
AP19
Digital input delay time
[float switch delay time]
24
Standard Modifications Note
rA
(A)
0,1
(Hz)
50
---
(bar)
1,5
Standard Modifications Note
(bar)
10
(s)
3
(s)
2 MT
0 MM
(s)
30
(s)
10
(s)
60
(bar)
1,5
3
oFF
SLA
1
0
(bar)
SLA1
0,3
(s)
10
0,6
(s)
30
4.93.410