Removal of the Pump from Pipework
Should it be necessary to remove the pump, follow these instructions:
1. Switch off the power and remove the plug from the power source.
NOTE: If the pump is wired into a time clock or another automatic control, the wiring
should be removed by a qualified electrician.
2. Close the water valves on the pool return and the pump inlet pipework.
3. Remove the discharge & suction barrel unions taking care not to lose the orings.
4. Move the pipework with the barrel unions attached until the pump can be pulled clear.
NOTE: When making any enquiries about your Silensor® be certain to quote the model
number from the nameplate located on motor.

Water Quality

Maintaining balanced water chemistry is important to the life of your pool pump. This pump is designed to
be used with Pool & Spa water, balanced in accordance with Langlier Saturation Index, with a pH level of
between 7.2 and 7.8 and is regularly treated with a chlorine sanitising agent with the level not exceeding
3000PPM. Salt levels should be maintained between 4000ppm - 6000ppm.
Please consult your local pool shop regularly to have your water tested.
The electrical connections and checks must be made by a qualified electrician and
comply with applicable local standards. Poor installation or poor power supply may
even result in electrical fires!
DANGER - Hazardous suction. Do not block water entry into filtration system with any
part of your body as the pressure can trap hair or body parts, causing severe injury or
death. Do not block suction. Turn off pump immediately if someone becomes trapped.
Caution! Do not add chemicals directly to the pool skimmer. Adding undiluted chemicals
may damage pump and filter and void warranty.
The appliance is not intended for use by young children or infirm persons without su-
pervision. Young children should be supervised to ensure that they do not play with the
appliance.
Routine Maintenance tasks – to maximise the life of your pool equipment & personal
safety, use this checklist once a week. Turn pump off first.
a. Make sure that any pressure gauges are in working condition and the operating pressure is
within limits as specified on the product.
b. Make sure that each suction inlet, and main drain has a cover that is securely attached and in
safe working condition.
c. Make sure that all skimmer covers are securely attached and in safe working condition. These
should be replaced every 3 to 4 years.
d. Remove any obstructions or debris from the main drain cover.
e. Ensure the skimmer baskets and the pump hair and lint pots are free of leaves and debris at
least once a week.
f. Remove obstructions and combustibles from around the pump motor.
g. Make sure all wiring connections are clean and that all wiring and electrical equipment is in
good condition. Damaged wiring must be repaired or replaced by a qualified electrician as
soon as damage is discovered.
h. Check water balance and sanitiser levels at your local pool shop.
WARNING! Pump suction is hazardous and can trap and drown or disembowel bathers.
Do not block suction. Do not use or operate swimming pools, spas or spa baths if
a suction cover is broken, missing or loose. Two suction covers and inlets must be
provided into every pump to avoid suction entrapment.
After Sales Service
For professional after sales service or repair contact your Davey Dealer.