BTL7-A/C/E/G501/504/505-... / BTL7-C/E508/509/512/513-...
Micropulse Configuration Tool
4

Menus

The menu commands can be called up via the menu bar
or directly using key combinations (shortcuts).
Clicking on
www
website. This requires that the PC be connected
to the Internet.
4.1

"File" menu

4.1.1
Open <Ctrl> + <O>
Opens the "Open" dialog box. A saved configuration can
be loaded (file extension "dat").
If the type is identical, a prompt appears and the
transducer can be updated.
If the prompt is not confirmed or the type is not identical,
the Micropulse Configuration Tool switches to offline mode
(see "Settings" menu, section 4.3).
4.1.2
Save <Ctrl> + <S>
Opens up the "Save" dialog box, a configuration can be
saved as a file (file extension "dat"). The configuration
currently located in the Micropulse Configuration Tool is
saved, regardless of whether it was sent to the transducer
or not.
4.1.3
Report <Strg> + <E>
Calls up a text file (temp.txt) that documents the
information on the transducer and its current settings. It
can be stored under a new name.
4.1.4
Quit <Control> + <X>
Quits the Micropulse Configuration Tool. If the transducer
is not yet updated, a prompt appears. Quitting can be
cancelled.
4.2

"Transducer" menu

4.2.1
Read <Ctrl> + <R>
The configuration of the connected transducer is read.
Reading must be acknowledged. The current configuration
in the Micropulse Configuration Tool will be overwritten.
4.2.2
Factory settings <Ctrl> + <F>
Resets the configuration of the connected transducer to
the factory settings. Resetting must be confirmed.
12
english
.
.
opens the Balluff
ballUff
com
4.2.3
Button lock (if calibration device is usable)
The function to manually adjust the transducer with the
calibration device can be locked, making configuration only
possible with the PC software. The button status is shown
in the main window.
The menu item "Button lock" and the button
status are only displayed if a transducer is
connected which can be set using the
calibration device.
The menu item is also only activated if the
transducer is configured as a standard unit:
One magnet
Both outputs are assigned the "Position"
function
Identical measuring range for both outputs.