LED INDICATORS:
POWER
Steadily lit: - Mains power on - Board powered - Fuse F1 intact
START
Lit: START input activated
OPEN
Lit: OPEN pedestrian input activated
STOP
Unlit: STOP input activated
PHOT
Unlit: PHOT photocell input activated
FAULT 1 PHOT input safety device test input diagnostics
BAR
Unlit: BAR safety edge input activated
FAULT 2 BAR input safety device test input diagnostics
Unlit: leaf fully closed
SWC
Lit: motor limit switch is disengaged
Unlit: leaf fully open
SWO
Lit: motor limit switch is disengaged
Unlit: no error
ERR
LIT: see error diagnostics table
Unlit: remote programming not active
Radio LED only fashing: Remote programming active, waiting for
hidden key.
RADIO
(GREEN)
Flashing in sync with Set LED: Transmitter deletion in progress
Lit: remote programming active, waiting for desired key.
Lit 1s: Radio receiver channel activated
Lit: Set key pressed / Autoset completed successfully
Flashes three times: Autoset in progress
Fast fashing 10s: Autoset failed
SET
Flashing in sync with Radio LED: Transmitter deletion in progress
Lit 1s: Start/Stop after key S3 pressed
Lit 10s: Autoset completed correctly

17) ADJUSTMENT PROCEDURE

- Before turning the unit on, check electrical connections.
- Set the following parameters: Automatic Closing Time, motor force, slow-down
distance.
- Set the logics.
- Run the autoset function.
WARNING! Incorrect settings can result in damage to property and injury
to people and animals.
WARNING: Check that the force of impact measured at the points
provided for by standard EN 12445 is lower than the value laid down
by standard EN 12453.
For best results, it is advisable to run the autoset function with the motors idle (i.e.
not overheated by a considerable number of consecutive operations)
18) INSTALLATION TEST PROCEDURE
1. Run the AUTOSET cycle (*)
2. Check the impact forces: if they fall within the limits (**) skip to point 9 of the
procedure, otherwise
3. Where necessary, adjust the sensitivity (force) parameter: see parameters table.
4. Check the impact forces again: if they fall within the limits (**) skip to point 9
of the procedure, otherwise
5. Apply a shock absorber profle
6. Check the impact forces again: if they fall within the limits (**) skip to point 9
of the procedure, otherwise
7. Apply pressure-sensitive or electro-sensitive protective devices (such as a
safety edge) (**)
8. Check the impact forces again: if they fall within the limits (**) skip to point 9
of the procedure, otherwise
9. Make sure all devices designed to detect obstacles within the system's operating
range are working properly
(*) Before running the autoset function, make sure you have performed all the
assembly and make-safe operations correctly, as set out in the installation
warnings in the drive's manual.
(**) Based on the risk analysis, you may fnd it necessary to apply sensitive
protective devices anyway
WARNING! Incorrect settings can result in damage to property and injury to people
and animals.
16 -
DEIMOS BT A 400 - DEIMOS BT A 600
INSTALLATION MANUAL
LED ERR:
Led SET
Unlit:
Lit
slow
fashing
Led ERR
Lit
slow fashing
Photocell test,
Reverse due to
Costa o Costa 8k2
obstacle - Ampe-
failed
rostop
- Check photocell
- Check for obsta-
connection and/or
cles in path
logic settings
Internal system
supervision control
error.
- Try switching the
board of and back
on again.
If the problem
persists, contact
the technical
assistance de-
partment.
Photocell test
failed
- Check photocell
connection and/or
logic settings
fast fashing
Thermal cutout
- Allow automated
device to cool
Limit switch error
- Check limit
switch connec-
tions
Parameters
and/
or Operating Logic
edited
- If the "Slow-down
distance" is edited,
run a new Autoset
cycle to confrm
the new setting.
- If other parame-
ters and/or opera-
ting logic are edi-
ted, hold down S2
for 5s to confrm.
NOTE: In any case,
the Autoset fun-
ction confrms all
changes made to
the board.