TABLE "A" - PARAMETERS
TRIMMER
Parameter
Automatic
T1
closing time [s]
T2
Leaf force [%]
Slow-down
T3
distance [%]
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
TABLE "B" - LOGICS
DIP
Logic
Transmitter
1
programming
2
BAR / 8K2
Photocell input
3
check
4
Edge input check
Photocells
5
during closing
6
Fast closing
Block pulses
7
during opening
8
3-step logic
INSTALLATION MANUAL
+
+
min.
max.
Waiting time before automatic closing.
0
120
NOTE: Set to 0 if not used.
Force exerted by leaf/leaves.This is the percentage of force delivered, beyond the force stored during the
autoset cycle (and subsequently updated), before an obstacle alarm is generated.
10
90
WARNING: It afects impact force directly: make sure that current safety requirements are met
with the set value (*). Install anti-crush safety devices where necessary.
Set opening slow-down speed as a percentage of total travel. This distance is travelled at low speed.
5
50
NOTE: When this parameter is edited, a new Autoset cycle must be run to confrm it.
Cross out
Default
Description
setting used
Enables wireless memorizing of transmitters:
1- Press in sequence the hidden key and normal key (T1-T2-T3-T4) of a transmitter that has already
been memorized in standard mode via the radio menu.
2- Press within 10 sec. the hidden key and normal key (T1-T2-T3-T4) of a transmitter to be memorized.
ON
The receiver exits programming mode after 10 sec.: you can use this time to enter other new
transmitters.
ON
This mode does not require access to the control panel.
IMPORTANT: Enables the automatic addition of new transmitters, clones and replays.
Disables wireless memorizing of transmitters and automatic addition of clones.
OFF
Transmitters are memorized only using the relevant Radio menu or automatically with replays.
IMPORTANT: Disables the automatic addition of new transmitters and clones
Input confgured as Bar 8k2. Input for resistive edge 8K2.
ON
The command reverses movement for 2 sec.
OFF
Input confgured as Bar, safety edge.
OFF
The command reverses movement for 2 sec.
ON
Enable safety check on the PHOT input
OFF
OFF
Safety check on PHOT input not enabled
ON
Enable safety check on the BAR input
OFF
OFF
Safety check on BAR input not enabled
In the event beam is broken, photocell operation is disabled during opening. During closing,
ON
movement is reversed immediately.
OFF
When beam is broken, photocells are active during both opening and clo-
OFF
sing. When beam is broken during closing, movement is reversed only once the
photocell is cleared.
ON
Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
OFF
OFF
Logic not enabled
ON
The start pulse has no efect during opening.
OFF
OFF
The start pulse has efect during opening.
Switches to 3-step logic; during closing, start
ON
reverses movement.
OFF
OFF
Switches to 4-step logic.
Description
CLOSED
DURING CLOSING
OPEN
DURING OPENING
AFTER STOP
DEIMOS BT A 400 - DEIMOS BT A 600 -
3 step
4 step
opens
opens
stop
closes
closes
stop +
stop +
TCA
TCA
opens
opens
15