your applIanCe

Automatic Safety Valve

These hobs have a safety device that automatically
closes the gas cock if the flame accidentally
goes out due to draughts, a pot spilling over, or a
temporary interruption of the gas supply. This device
is activated approx. 30 seconds after the flame goes
out.
FH FS 785 4G
Burner
AUX
SR PLUS
SR
R
TC
FH FS 584 4G
Burner
AUX
SR
R
The use of larger pots than those specified can
cause excessive overheating of the knobs and top
and, in case of prolonged use, yellowing of the cover
(if in stainless steel).

operaTIon

Lighting the burners

The hob is lit with the control knobs. To light the
burners, proceed as follows:
Press and turn the required knob to the lighting
X
X
and max delivery position.
Keep the knob pressed down for 3-4 seconds to
X
X
allow the sparks to ignite the gas coming out the
flame spreader and to allow the thermocouple to
heat up.
FH FS 785 4G / FH FS 584 4G

Burner use

For lower gas consumption and better efficiency use
pots of widths suitable for the burners, making sure
the flame does not go beyond the edges (comply
with the table below).
Ensure that the room is well ventilated.
X
X
Pan bottom max. Ø (recommended)
Pan bottom max. Ø (recommended)
Franke declines any liability for damage due to such
use.
Then release the knob and, turning it
X
X
anticlockwise adjust the flame as required. If the
flame does not stay alight, repeat the operations
from step 1.
– 9 –
140 mm
200 mm
200 mm
260 mm
280 mm
140 mm
200 mm
260 mm
EN