In the horizontal runs the exhausting pipe must be slightly
slanted (about 10°) and directed upwards to vent the air easily
from the room to the outside.
Attention! If the hood is supplied with active charcoal filter,
then it must be removed.
Connect the hood and discharge holes on the walls with a
diameter equivalent to the air outlet (connection flange).
Using the tubes and discharge holes on walls with smaller
dimensions will cause a diminution of the suction performance
and a drastic increase in noise.
Any responsibility in the matter is therefore declined.
!
Use a duct of the minimum indispensible length.
!
Use a duct with as few elbows as possible (maximum
elbow angle: 90°).
!
Avoid drastic changes in the duct cross-section.
!
Use a duct as smooth as possible inside.
!
The duct must be made of certified material.

Filter version

The aspirated air will be degreased and deodorised before
being fed back into the room.
In order to use the hood in this version, you have to install a
system of additional filtering based on activated charcoal.
The models with no suction motor only operate in ducting
mode, and must be connected to an external suction device
(not supplied).
The connecting instructions are supplied with the peripheral
suction unit.

Installation

The minimum distance between the supporting surface for the
cooking equipment on the hob and the lowest part of the
range hood must be not less than 50cm from electric cookers
and 65cm from gas or mixed cookers.
If the instructions for installation for the gas hob specify a
greater distance, this must be adhered to.
Electrical connection
The mains power supply must correspond to the rating
indicated on the plate situated inside the hood. If provided with
a plug connect the hood to a socket in compliance with current
regulations and positioned in an accessible area, after
installation. If it not fitted with a plug (direct mains connection)
or if the plug is not located in an accessible area, after
installation, apply a double pole switch in accordance with
standards which assures the complete disconnection of the
mains under conditions relating to over-current category III, in
accordance with installation instructions.
Warning! Before re-connecting the hood circuit to the mains
supply and checking the efficient function, always check that
the mains cable is correctly assembled.
The hood is provided with a special power cable ; if the cable
is damaged, request a new one from Technical Service.
Mounting
Before beginning installation:
Check that the product purchased is of a suitable size for
the chosen installation area.
Remove the charcoal (*) filter/s if supplied (see also
relative paragraph). This/these is/are to be mounted only
if you want lo use the hood in the filtering version.
Check (for transport reasons) that there is no other
supplied material inside the hood (e.g. packets with
screws (*), guarantees (*), etc.), eventually removing
them and keeping them.
If possible, disconnect and move freestanding or slide-in
range from cabinet opening to provide easier access to
rear wall/ceiling. Otherwise put a thick, protective
covering over countertop, cooktop or range to protect
from damage and debris. Select a flat surface for
assembling the unit. Cover that surface with a protective
covering and place all canopy hood parts and hardware
in it.
In addition check whether near the installation area of the
hood (in the area accessible also with the hood mounted)
an electric socket is available and it is possible to
connect a fumes discharge device to the outside (only
suction version).
Carry out all the masonry work necessary (e.g.
installation of an electric socket and/or a hole for the
passage of the discharge tube).
This type of cooker hood must be fixed to the ceiling.
Very heavy product; hood handling and installation must
be carried out by at least two persons.
Attention! Before connecting the hood to the electrical
mains.
If you have an Elica hob:
Perform the electrical connections of the hood and Elica
hob at the same time to ensure the logical connection
between the hood and Elica hob (also refer to the
paragraph ''Operation-Adjusting the parameters for
automatic
operation-Sensor
''Operation-Adjusting the parameters for automatic
operation-Logical connection between hood and
Elica hob'').
If you do NOT have an Elica hob:
In this case, after being connected to the mains, the hood
will still try connecting to a hob.
Wait for the hood to complete the connection attempts
(approximately 5 minutes) and then disable the electronic
connection module as follows:
With the hood switched off, simultaneously press and
hold keys
(see Operation paragraph). The hood emits an acoustic
signal (beep) indicating that the disabling process is
complete.
Reactivating the connection module between the
hood and Elica hob: With the hood switched off,
20
calibration''
and
for more than 10 seconds,
and