(see zoom in Fig. 6).
- turn the machine upside down, letting it rest on the
handgrip. With the protection of a leather glove, grasp
an end of the saw blade, holding it steady.
Do not perform this operation without
using the protection of a glove.
- loosen the screws M (Fig. 7) that hold down the blade
and replace the worn-out one with a new blade of the
same characteristics.
- for reassembly, perform the preceding operations in
inverse order.
Ensure that the saw disc bearing is com-
pletely free of glue, sawdust, dust, etc,
before mounting the new disc.
12. CONNECTING
In order to connect the machine to an AS182K or
AS282K aspirator or other external aspiration source,
fix the aspiration coupling included with the unit to the
machine's aspiration inlet N (Fig. 1).
The chosen external aspiration source may then be
hooked up to the other end of the aspiration coupling.
The brackets A2 (Fig. 1) that are attached to the dust
collection tube allow the mains cable to be inserted,
making it easier to manoeuvre.
13. MAINTENANCE OF THE BRUSHES
AND THE COLLECTOR
Disconnect the machine from the mains
before carrying out any maintenance
work.
Change the brushes when they are a minimum of 9
mm long.
Changing the brushes.
Remove cover O by undoing the five screws P that hold
it in place (Fig. 8). Use small screwdriver R to remove
brush holder Q. Put the screwdriver into one of the
two slots and use it as a lever (Fig. 8). Move the end of
spring S back. Holding it in this position, remove used
brush T and replace it with a new original VIRUTEX
brush. Put the brush holder back in place, ensuring
that it fits snugly into the carcass and that each of
the brushes press gently on the collector. The position
of the connection terminal of the brush in the brush
holder is shown on the carcass of the machine with the
symbol V to facilitate replacement. Ensure that when
the cover is replaced, the clamps of the brush holder
10
do not pinch the cable.
Screw cover P back into place. We advise that you
leave the machine on but without using it for 15
minutes so that the brushes can self-adjust.
If you observe any burning or protruding
of the collector, take it to a VIRUTEX
technical service outlet to be repaired.
Never use emery paper for this operation.

14. LUBRICATION AND CLEANING

The machine comes fully lubricated from the factory
and does not require special care.
Always carefully clean the machine after use and
periodically oil the guides Z (Fig. 5), making sure they
are never left dry.
Keep the power cable in perfect condition.
Keep the machine's vent and cooling openings clean
and unobstructed.
15. NOISE AND VIBRATION LEVEL
The noise and vibration levels of this device have been
measured in accordance with European standard EN
60745-2-19 and EN 60745-1 and serve as a basis for com-
parison with other machines with similar applications.
The indicated vibration level has been determined for
the device's main applications and may be used as an
initial value for evaluating the risk presented by expo-
sure to vibrations. However, vibrations may reach levels
that are quite different from the declared value under
other application conditions, with other tools or with
insufficient maintenance of the electrical device or its
accessories, reaching a much higher value as a result
of the work cycle or the manner in which the electrical
device is used.
Therefore, it is necessary to establish safety measures
to protect the user from the effects of vibrations, such
as maintaining both the device and its tools in perfect
condition and organising the duration of work cycles
(such as operating times when the machine is subjected
to loads, and operating times when working with no-load,
in effect, not in use, as reducing the latter may have a
considerable effect upon the overall exposure value).

16. WARRANTY

All VIRUTEX power tools are guaranteed for 12 months
from the date of purchase, excluding any damage which
is a result of incorrect use or of natural wear and tear
on the machine. All repairs should be carried out by the
official VIRUTEX technical assistance service.
VIRUTEX reserves the right to modify its products wi-