AXIS Q7401 Installation Guide
I/O terminal connector - Used in applications for e.g. motion
detection, event triggering, time lapse recording and alarm
notifications. In addition to an auxiliary power and a GND pin, the
AXIS Q7401 has 4 pins that can be configured as either input or out
put. These pins provide the interface to:
Transistor output - For connecting external devices
such as relays and LEDs. Connected devices can be activated by AXIS VAPIX API, output
buttons on the Live View page or by an Event Type. The output will show as active
(shown under Event Configuration > Port Status) if the alarm device is activated.
Digital input - An alarm input for connecting devices that can toggle between an open
and closed circuit, for example: PIRs, door/window contacts, glass break detectors, etc.
When a signal is received the state changes and the input becomes active (shown
under Event Configuration > Port Status.).
Function
Pin number
GND
1
12VDC
2
Power
Configurable
3 - 6
(Input or
Output)
Notes
Ground
Can be used to power auxiliary equipment.
Notes:
• This pin can only be used as power out.
• Same voltage as pin 2 of the power
connector.
Digital input - Connect to GND to activate, or
leave floating (or unconnected) to deactivate.
Digital output - Uses an open-drain NFET
transistor with the source connected to GND.
If used with an external relay, a diode must
be connected in parallel with the load, for
protection against voltage transients.
Page 13
Specifications
Max load = 100mA
Min input = - 40V DC
Max input = + 40V DC
Max load = 100mA
Max voltage = + 40V DC