If it is not possible to protect the high pressure cleaner in cold areas as described above, it must be brought into
a warm room for the time required to melt any ice which may have formed inside it before attempting to start it
up again.
If these instructions are not followed, the high pressure cleaner may be seriously damaged.
7 C
leanInG
and
WArnIng
• Only start cleaning and maintenance once the instructions in the "Switching off" section have been
completed.
It is particularly important to always disconnect the electricity supply.
• To safeguard the safety of the high pressure cleaner, only use the original spare parts supplied by the Manufacturer
or those endorsed by him.
• The rubber pipes, the coupling and the high-pressure lances are important for safety: only use those endorsed by
the Manufacturer.
7.1 r
m
outIne
aIntenanCe
Follow the instructions in the "Switching off" section and abide by the recommendations in the table below.
INTERVAL FOR MAINTENANCE
Each time used
Weekly
Monthly
cAUtIon
• During use, the high pressure cleaner should not be too noisy and large amounts of water or oil should not drip
from underneath it.
In this event, a Skilled technician should test the appliance.
7.2 s
m
peCIal
aIntenanCe
WArnIng
Only Skilled Technicians are authorised to carry out special maintenance.
Follow the instructions in the table below for special maintenance.
INTERVAL FOR MAINTENANCE
Every 50 hours
Every 100 hours
cAUtIon
• the data in the table are indications.
24
m
aIntenanCe
ACTION
• Check the supply cable, high-pressure pipe, couplings, cleaner gun, lance
pipe.
Should any of these parts appear to be damaged, do not use the high
pressure cleaner and contact a Skilled Technician.
• Cleaning the water inlet filter
Remove the water inlet fitting (a) and remove the filter (b) with pliers (see Fig. 5).
Cleaning the filter under running water or a burst of compressed air is usually
sufficient. For tougher dirt, use a product for removing lime scale or replace it.
Contact an authorised service centre to make sure you get the right spare part.
Replace the filter and secure the coupling fully.
• Clean the nozzle.
For cleaning, it is generally enough to pass the supplied pin (19) inside the
nozzle hole. In case you do not obtain any appreciable result, apply to an
authorised service centre.
ACTION
Check the pump hydraulic circuit.
Check the pump fixing.
Replace the pump oil.
Check the pump suction/delivery valves.
Check the pump screws are tightened.
Check the pump adjustment valve.
Check the safety devices.