Herunterladen Inhalt Inhalt Diese Seite drucken

Description; Technical Specification - Parker MIDIGAS 2 Benutzerhandbuch

Stickstoffgenerator der midigas-reihe
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 58

2 Description

The MIDIGAS range of nitrogen generators operate on the Pressure Swing Adsorption (PSA) principle to produce a continuous stream of
nitrogen gas from clean dry compressed air.
Dual chamber columns, filled with extruded beads of adsorbent (Carbon Molecular Sieve [CMS]) material, are joined via an upper and lower
manifold to produce a two bed system. Compressed air enters the bottom of the 'on-line' bed and flows up through the CMS. The oxygen,
carbon dioxide, humidity and non-methane hydrocarbons are preferentially adsorbed by the CMS allowing clean dry nitrogen to pass through.
After a pre-set time the control system automatically switches the bed to regenerative mode. All of the contaminants are vented from the CMS
and a small portion of the outlet nitrogen gas is expanded into the bed to accelerate the regeneration. At the same instant the second bed
comes on-line and takes over the separation process.
The CMS beds alternate between separation and regeneration modes to ensure continuous and uninterrupted nitrogen production.
The oxygen concentration in the nitrogen stream is analysed continuously. If the concentration exceeds the required production level, the
nitrogen outlet is closed and the gas is vented to atmosphere. Normal operation will resume when the purity recovers.

2.1 Technical Specification

UNITS
Flowrate
MIDIGAS 2
m
MIDIGAS 4
m
MIDIGAS 6
m
Outlet Pressure
bar g
psi g
Stated flows are for operation at 7 bar g (100 psi g / 0.7 MPa g) with reference to 25ºC.
Inlet Parameters
Inlet Air Quality
Inlet Pressure
Inlet Temperature
Port Connections
Air Inlet
N
Outlet to Buffer
2
N
Inlet from Buffer
2
N
Outlet
2
Electrical Parameters
Generator Supply
Generator Power
(Anti Surge (T), 250v, 5 x 20mm HBC,
Fuse
Breaking Capacity 1500A @ 250v,
Max Dryer Power*
Notes:
The generator does not require adjustment when connecting to 115v and 230v electrical supplies.
The power rating specified is for the generator alone and does not take in to account any pre-treatment dryer connected to the dryer supply terminals of the generator
* The dryer is fed directly from the generator supply.
10ppm
100ppm
3
0.55
1.2
/hr
cfm
0.3
0.7
3
1.2
2.4
/hr
cfm
0.7
1.4
3
1.5
3.2
/hr
cfm
0.9
1.9
5.6
5.4
81.2
78.3
ISO 8573-1: 2001 Class 3.2.2
6 – 13 bar g
88 – 188.5 psi g
o
5 – 50
C
o
(41 – 122
F)
G1/2
G1/2
G1/2
G1/2
115 / 230 ± 10% Vac 50/60 Hz
80 W
3.15 A
IEC 60127, UL R/C Fuse)
100W
250ppm
500ppm
0.1%
1.5
1.9
2.4
0.9
1.1
1.4
3.2
3.9
4.7
1.9
2.3
2.8
4.2
5.3
6.5
2.5
3.1
3.8
5.9
5.7
5.6
85.6
82.7
81.2
Environmental Parameters
Ambient Temperature
Humidity
IP Rating
Pollution Degree
Installation Category
Altitude
Noise
Packed Weights and Dimensions
MIDIGAS 2
MIDIGAS 4
MIDIGAS 6
0.5%
1%
2%
3%
3.4
4.3
5.8
7.2
2.0
2.5
3.5
4.2
6.9
8.5
11.6
14.3
4.1
5.0
6.8
8.4
9.5
11.5
15.2
18.7
5.6
6.8
8.9
11.0
5.7
6.0
6.0
5.8
82.7
87.0
87.0
84.1
o
5 – 50
C
o
(41 – 122
F)
d
o
29% @ 50
C (80%
MAX
IP20 / NEMA 1
2
II
< 2000 m
(6562 ft)
<80 dB (A)
Dimensions
mm / (ins)
H
W
D
612
1490
950
(24.48)
(59.6)
(38)
612
1490
950
(24.48)
(59.6)
(38)
612
1490
950
(24.48)
(59.6)
(38)
4%
5%
8.4
9.4
4.9
5.5
16.7
18.8
9.8
11.1
21.7
24.5
12.8
14.4
5.7
5.6
82.7
81.2
o
31
C)
Weight
Kg / (lbs)
174
(383.6)
221
(487.2)
272
(597.7)
.
3

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Midigas 4Midigas 6

Inhaltsverzeichnis