FUNCTIONS
START ALARM
Alarm is activated also with panel off when, while connected with the 230V net, start key is operated.
Alarm signals acoustically and visually with the message "230V CONNECTION" and then blinking of
symbols ref. 02 and 04.
CAR BATTERY ALARM (B1)
When car battery voltage is lower than 12V, the "MOT. B. DISCHARGE" alarm is activated automatically
and symbols ref. 06 and 07 start blinking.
CAR BATTERY RECHARGE (B1)
With battery charger or solar panel: an electronic device controlled by the microprocessor allows the
recharge (max 4A) of car battery (B1) only if it has a voltage lower than 12,5V and if the voltage of
leisure battery is bigger than 13.6V.
Priority is given to leisure battery (B2) charge.
Function is displayed by the symbol ref. 03 on control panel.
With solar panel the device is operated only when control panel is on, when 230V net is connected the
device is automatically operated.
LEISURE BATTERY ALARM (B2)
When leisure battery voltage is lower than 11V, "LEIS. B. RESERVE" is automatically activated together
with symbols ref. 05 and 07 blinking.
When leisure battery voltage is lower than 10,5V, "LEIS. B. DISCHARGE" alarm is activated.
LEISURE BATTERY RECHARGE (B2)
a)
through engine alternator: through separative relays when engine is on. The ignition electronically
controls the relays: parallel, fridge, awning light, etc.
b)
trough 230V net: pad system through battery charger (see BATTERY CHARGER)
c)
trough solar panel: through solar charge regulator.
MINIMUM VOLTAGE CONTROL (BATTERY PROTECTION)
The electronic battery protection device cuts off the 12V users in
battery is discharging.
- The first step is at 10V and disables: right and left neon lights, pump, lights, radio, awning light,
controlled internal light, engine heating, auxiliary exit and 12V sockets.
- The alarm is signalled acoustically (2 short beeps) and visually with the message "BATTERY
SAVER" and by the blinking of symbol ref. 08.
- The second step is at 9,8V and disables: stove, "Eis-ex" anti-ice resistor, gas valve, gas detector
and control panel.
- The third step is at 9,5V and disables: alimentation of the gas piezoelectric device and boiler's
anti-ice valve.
When voltage is bigger than 10,5V, it is possible to reactivate all users for one minute by pressing the
on/off button (ref. 01 on control panel) or separately by pressing the related control button.
Users are automatically reactivated when voltage is bigger than 12,5V.
This device doesn't control the functions: fridge, step and the auxiliary exit RES.
TANKS
a)
Drink water tank with electronic probe: visualization in "%" with numerical indication, and graphically
with represented tank filling.
b)
Recovery water tank: electronic probe: visualization in "%" with numerical indication, and graphically
with represented tank filling.
c)
Sewage water tank: three level probe: visualization in "%" with numerical indication, and graphical
with represented tank filling.