Herunterladen Inhalt Inhalt Diese Seite drucken

Connecting An External Aerator Pump; Commissioning/Start-Up - Oase ProfiClear Premium Compact EGC Gebrauchsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
N O T E
If the ground is hard:
► Protect the control system from knocks/impact.
► Push both ground stakes onto the control system.
► With light pressure push the ground stakes into the ground to mark the position.
► Detach the ground stakes from the control system and drive them into the ground.
Then push the control system onto the stakes.
4.5

Connecting an external aerator pump

► Connect the aerator rods in the container to an external aerator pump.
OASE recommends: OASE AquaOxy 2000 pond aerator.
How to proceed:
 P
1. Connect the hose from the external aerator pump to the air connection and fit the air connection onto
the container.
– For thinner ∅ 4 mm air hoses, use the 4/9 mm adapter and secure the connection with a cable
binder if necessary.
N O T E
Ensure that the aeration is not too high during the filter start-up phase. Excessive turbulence delays the
initial colonisation of micro-organisms. We recommend approx. 1000 l/h.
5

Commissioning/start-up

► Thoroughly clean the pond before starting up the filter system for the first time to ensure that the filter
system is not overloaded by excessively soiled water. OASE recommends using the PondoVac pond
vacuum cleaner for cleaning the pond.
– This cleaning measure is normally not necessary for newly installed ponds.
► It is necessary to operate the filter system for 24 hours a day during the pond season.
W A R N I N G
Possible death or severe injury from hazardous electrical voltage!
► Prior to reaching into the water, isolate (switch off and disconnect) all units/devices used in the water.
► Isolate the device (disconnect from the power supply) before carrying out any work on it.
N O T E
A dimmer or timer will destroy the device.
► Only connect the device to a power supply without dimmer.
► Do not use a timer.
N O T E
Never allow the rinsing pump to run dry. Possible consequences: The rinsing pump will be destroyed.
► Check the water level at regular intervals. Ensure that the rinsing pump is always under water during
operation.
► Do not switch on the control system until the container is flooded with water.
- EN -