TECHNICAL SPECIFICATIONS
TT10
Nominel ydelse
6kW
Height:
1009mm
Width:
518mm
Depth:
462mm
Weight ca.:
117kg
Average values for testing of TT10 models:
Exhaust gas temperature 320 °C
Exhaust gas mass flow
Efficiency
Nominal Heat output
Flue draught
SUPPLEMENTARY INSTALLATION INSTRUCTIONS FOR THE UK MARKET
TO BE READ IN CONJUNCTION WITH THOSE IN THE INSTRUCTION BOOKLET
READ THE INSTRUCTION BOOKLET AND THESE SUPPLEMENTARY INSTRUCTIONS CARE-
FULLY BEFORE INSTALLATION
These instructions together with those in the instruction booklet cover the basic principles to en-
sure the satisfactory installation of the stove, although detail may need slight modification to suit
particular local site conditions.
In all cases the installation must comply with current Building Regulations, Local Authority Byelaws
and other specifications or regulations as they affect the installation of the stove.
It should be noted that the Building Regulations requirements may be met by adopting the rele-
vant recommendations given in British Standards BS 8303, BS EN 15287-1:2007 as an alternative
means to achieve an equivalent level of performance to that obtained following the guidance given
in Approved Document J.
Please note that it is a legal requirement under England and Wales Building Regulations that the
installation of the stove is either carried out under Local Authority Building Control approval or
is installed by a Competent Person registered with a Government approved Competent Persons
Scheme. HETAS Ltd operate such a Scheme and a listing of their Registered Competent Persons can
be found on their website at www.hetas.co.uk.
CO Alarms:
Building regulations require that when ever a new or replacement fixed solid fuel or wood/biomass
appliance is installed in a dwelling a carbon monoxide alarm must be fitted in the same room as
the appliance. Further guidance on the installation of the carbon monoxide alarm is available in BS
EN 50292:2002 and from the alarm manufacturer's instructions. Provision of an alarm must not be
considered a substitute for either installing the appliance correctly or ensuring regular servicing and
maintenance of the appliance and chimney system.
HEALTH AND SAFETY PRECAUTIONS
Special care must be taken when installing the stove such that the requirements of the Health and
Safety at Work Act are met.
Handling
Adequate facilities must be available for loading, unloading and site handling.
Fire Cement
Some types of fire cement are caustic and should not be allowed to come into contact with the skin.
In case of contact wash immediately with plenty of water.
Asbestos
This stove contains no asbestos. If there is a possibility of disturbing any asbestos in the course of
installation then please seek specialist guidance and use appropriate protective equipment.
Metal Parts
When installing or servicing this stove care should be taken to avoid the possibility of personal
injury.
TT10S
6kW
1044mm
525mm
490mm
190kg
4.5 g/s
82%
6 kW
12 Pa
TT10HS
TT10G
6kW
6kW
1279mm
1009mm
525mm
518mm
490mm
462mm
220kg
116kg
23