SPECIFIC ATIONS
1)
Fuse signalling Led: it go "on" when the fuse is broken, and only if a load is connected to the battery.
2)
Connector for the temperature sensor connection.
3)
Switch for operation with or without temperature sensor.
NB: if the temperature sensor isn't connected make sure the switch is "O", otherwise the battery
charger doesn't operate.
4)
Switch for the choice of the battery type connected: "Pb" lead-acid, "Gel" GEL.
5)
Red LED indicating the recharge period (14,4V), green LED indicating the maintenance period
(13,8V).
6)
On/off security switch.
7)
Positive terminal to connect to the battery.
8)
Negative terminal to connect to the battery.
9)
Mains cable (230V).
10)
Signal 12V 50mA, indicating the battery charger is connected to the mains (230V).
11)
Protection fuses of the battery,
12)
Air outlet with cooling fan, operates only when the battery charger is in the charge period.
13)
Battery temperature sensor (optional).
Place the sensor on the top of the battery (using PVC tape) and where it can be influenced by other
heat sources.
CHARGING LINE IUoU
- mod. "A2018" 1 fuse 25A
- mod. "A2035" 2 fuses 25A.
14,5V
13,8V
13,3V