set them accordingly . Leave the two transmitters
switched on so that the channels already used will
be skipped during the channel scan for the second
receiver . Then perform the channel scan for the
second receiver, switch on the two appropriate
transmitters and set them accordingly .
6.1.2 Manual channel selection
If both receiving units A and B are switched on:
1) Keep the button SET pressed until the channel
indication for receiving unit A starts flashing on
the display .
2) Use the button  or  to select the channel
for receiving unit A, then press the button SET
to confirm .
3) The channel indication for receiving unit B starts
flashing on the display . Use the button  or 
to select the channel for receiving unit B, then
press the button SET to confirm .
If only one receiving unit A or B is switched on:
Keep the button SET pressed until the channel in-
dication starts flashing on the display . Select the
channel with the button  or  and then confirm
with the button SET .
If a channel is not confirmed within 10 seconds
with the button SET, the setting mode will be exited
and the channel previously set will be kept .
Note: The receiving units A and B cannot be set to the
same channel .
6.1.3 Setting the squelch
The squelch function will mute the respective
receiving unit when the level of the radio signal
falls below the threshold value adjusted . Thus, in-
terference signals will not cause noise when the
transmitter is switched off or when its radio signal is
insufficient: If the levels of the interference signals
are below the threshold value, the receiving unit
will be muted .
A high threshold value offers high interference
resistance, but it will also reduce the transmission
range . Thus, when the reception is good, a high
threshold value can be used; however, when the
transmitter and the receiver are far apart, a low
threshold value is recommended .
All rights reserved by MONACOR
reproduced in any form or by any means for any commercial use.
INTERNATIONAL GmbH & Co. KG. No part of this instruction manual may be
®
1) Switch off the receiving units A and B . Then
keep the button SET pressed, while switching
on a receiving unit . The display will indicate the
group setting (
or
2) To exit the group setting mode and to go to the
squelch setting mode, press the button SET: The
display will indicate
current value (flashing) .
3) Use the button  or  to set the value (level 7
= highest threshold value) .
4) To exit the squelch setting mode, press the but-
ton SET .
Note: The setting modes will be automatically exited after
5 seconds if no button is pressed . Any settings you may
have made will be saved .

7 Specifications

Radio frequencies
Channel
Frequency
1
863 .1 MHz
2
864 .1 MHz
3
863 .6 MHz
4
864 .6 MHz
5
863 .3 MHz
6
864 .3 MHz
7
863 .8 MHz
8
864 .8 MHz
Transmission range*: . . . . . approx . 50 m
Output level
XLR (bal .): . . . . . . . . . . . . . 30 mV
6 .3 mm jack (unbal .): . . . . 730 mV (HIGH)
Power supply: . . . . . . . . . . . via PSU supplied
Dimensions (W × H × D): . . 215 × 44 × 210 mm
Weight: . . . . . . . . . . . . . . . 1 .2 kg
* depending on local conditions
Subject to technical modification .
, with the digit flashing) .
(for "Squelch") and the
Channel
Frequency
9
863 .2 MHz
10
864 .2 MHz
11
863 .7 MHz
12
864 .7 MHz
13
863 .4 MHz
14
864 .4 MHz
15
863 .9 MHz
16
864 .9 MHz
80 mV (LOW)
and connected to
230 V~ / 50 Hz
(w / o antennas and
feet)
9