1.1.3 Temperature display in °C or °F:
DIP switch ON:
Temperature display in °F
DIP switch OFF:
Temperature display in °C
(factory setting)
Save the entry by pressing the DIP switch reset button
(also refer to Fig.
).
1.1.4 Control action: DIP switches 4 and 5
DIP switch 4 ON and 5 ON:
Adaptive control for all types of application.
DIP switch 4 ON and 5 OFF:
For fast controlled systems, applications at locations with
great temperature variations.
DIP switch 4 OFF and 5 ON:
For normal controlled systems, applications at locations
with normal temperature variations.
DIP switch 4 OFF and 5 OFF:
For difficult controlled systems, 2-position controller with
a switching differential of 0.5 °C (factory setting).
Save the entry by pressing the DIP switch reset button
(also refer to Fig.
).
1.1.5 Periodic pump run: DIP switch 6
Can only be used when circulating pump or valve is controlled!
2
Accessing the expert level
Move the selector slider to the RUN position and press simultaneously
press simultaneously
and
level for making the settings on that level.
Starting with code 00, the display shows the choice of languages. Navigation on the expert level is made possible with
settings by pressing
.
The expert level is quit by pressing the operating mode selection button
Code list
Function block
Code
00
Basic settings
01
02
10
LCD settings
11
12
30
Clock settings
31
32
Note 1:
If the radio clock is not active or not present, this setting has no impact.
With the radio clock active, the time signal received from Frankfurt is shifted by the value set under code 30 (time zone).
Note 2:
If the radio clock is not active or not present, the time change always takes place at 02:00 on the Sunday before the set date.
With the radio clock active, the time change is shifted by the value set under code 30 (time zone).
Note 3:
If the radio clock is not active or not present, the time change always takes place at 03:00 on the Sunday before the set date.
With the radio clock active, the time change is shifted by the value set under code 30 (time zone).
3

Function check

a) Check the display. If there is no display, check the batteries
b) "Continuously Comfort mode"
c) Set the temperature setpoint to a level above the displayed room
temperature (see operating instructions)
d) The relay and thus the actuating device must respond within 1
minute. Symbol
appears on the display. If not:
·
Check actuating device and wiring
·
The room temperature is possibly higher than the adjusted
temperature setpoint
CE1G2203xx
PID self-learning
PID 6
PID 12
2-Point
for 3 seconds, release
and keep
on display (also refer to Fig. G).
Name
Language
Sensor calibration
Switching differential 2-point
Illumination time
Background brightness
Contrast
Time zone
Deviation from time signal received from Frankfurt
(Central European Time CET) (refer to Note 1)
Start of summer time (refer to Note 2)
End of summer time (refer to Note 3)
, read the temperature displayed
DIP switch 3
This function protects the pump or valve against seizing during longer
off periods. Periodic pump run is activated for 3 minutes every 24
hours at 12:00 (display showing symbol
DIP switch ON:
DIP switch OFF:
Save the entry by pressing the DIP switch reset button.
1.1.6 Radio clock: DIP switch 7
Can only be used with REV..DC (with integrated DCF77 receiver for
time signal from Frankfurt)!
DIP switch ON:
DIP switch OFF:
Save the entry by pressing the DIP switch reset button
(also refer to Fig.
1.1.7 DIP switch reset
When changing one or several DIP switch positions, press the DIP
switch reset button to make a DIP switch reset.
Otherwise, the previous settings will be maintained!
(Also refer to Fig.
and
for 3 seconds, then release the buttons and, within 3 seconds,
depressed for another 3 seconds. This enables you to access the expert
.
e) Set temperature setpoint of "Continuously Comfort mode"
required level
f)
Select the required operating mode
2015-02-27
).
Pump run on (also refer to Fig.
Pump run off (factory setting)
quartz
Clock runs on built-in
Time signal DCF77 from Frankfurt
).
).
and
. Confirm the
Factory setting
Your setting
English
off
0.5°C
10 seconds
0
0
0 hours
March 31 (31-03)
October 31 (31-10)
DE
EN
)
FR
IT
NL
ES
PT
CS
HU
PL
SV
FI
DA
TR
EL
to the
7/48

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis