Mounting notes REV17..
EN
1
Placement of unit
FR
·
The REV17.. should be mounted in the main living room (for wall
mounting, refer to Figs. B through E)
IT
·
The REV17.. must be located such that it can acquire the room
temperature as accurately as possible, without getting affected by
NL
direct solar radiation or other heat or refrigeration sources
ES
PT
CS
HU
PL
SV
Commissioning
FI
1
Switching on the REV17..
DA
·
Remove the black battery transit tab (Fig. F); as soon as the tab
TR
is removed, the unit is ready to operate (also refer to operating
instructions)
EL
2
Selecting the language
·
When starting up, the display shows the type of controller at top
left and "THANK YOU ..." in all available languages on the text
line
Configuration and function check REV17.
1
Configuration
1.1
DIP switches
ON /
Sensor calibration on
See
1.1.1
Sensor calibration off
Setpoint limitation
16...35 °C
1.1.2
Setpoint limitation
3...35 °C
Temperature display °F
1.1.3
Temperature display °C
PID self-learning
PID 6
1.1.4
PID12
2-Point
1.1.1 Sensor calibration: DIP switch 1
Set the DIP switch to ON and press the DIP switch reset button:
The display shows CAL. The room temperature currently acquired
blinks.
Press
or
to make a recalibration of max. ± 5 °C. To save
the entry, set the DIP switch to OFF and press the DIP switch reset
button (also refer to Fig.
6/48
min.
10 cm
OFF
1
2
Factory setting: All DIP switches
).
2
Mounting
·
Refer to Figs. A through E
3
Checking the wiring
For electrical connections, refer to "Connection diagram".
Note:
Do not use stranded wires, only solid wires
or stranded wires with ferrules!
4
Notes
·
The local regulations for electrical installations must be complied
with
·
If the reference room is equipped with thermostatic radiator
valves, they must be set to their fully open position
·
External preliminary protection with max. C 10 A circuit breaker is
required in all cases
·
Press one of the buttons to stop the running display. The choice
of languages starts with "ENGLISH" (factory setting). Press
or
move the slider to confirm the selected language (also refer to
Fig. G)
3
4
5
6
7
When changing one or several
DIP switch positions, a DIP
switch reset must be made by
pressing the DIP switch reset
button (also refer to Fig.
Otherwise, the previous
settings will be maintained!
1.1.2 Setpoint limitation: DIP switch 2
DIP switch ON:
DIP switch OFF:
Save the entry by pressing the DIP switch reset button.
2015-02-27
until the language you require appears. Press
Periodic pump run on
Periodic pump run off
Quartz
Radio clock
DIP switch reset
ON
1
2
)
OFF
Setpoint limitation 16...35 °C
Setpoint limitation 3...35 °C
(factory setting)
or
See
1.1.5
1.1.6
1.1.7
3
4
5
6
7
8
9
CE1G2203xx