Labels

The machine is fitted with labels containing
important information about personal safety and
machine maintenance. The labels shall be in such
condition that they are easy to read. New labels can
be ordered from the spare parts list.
Data plate
Machine type
A.
Maximum permitted compressed air pressure
B.
C.
Serial number
D.
The warning symbol together with the book
symbol means that the user must read the
safety and operating instructions before the
machine is used for the first time.
The CE symbol means that the machine is
E.
EC-approved. See the EC declaration which is
delivered with the machine for more
information. If the CE symbol is missing, it
means that the machine is not EC-approved.
Noise level label
The label indicates the guaranteed noise level
corresponding to EC-directive 2000/14/EC. See
"Technical data" for accurate noise level.
9800 0608 90d | Original instructions
www.CrowderSupply.com • Toll Free: 888-883-5144
Safety and operating instructions
Safety label
To avoid injury, before using or servicing tool, read
and understand separately provided safety
instructions.

Installation

Hoses and connections

Compressed air source
A.
Water separator (optional)
B.
C.
Oiler (optional)
D.
Max. 10 feet (3 meter) compressed air hose
between the oiler and the machine.
Check that you are using the correct
recommended operating pressure, 87 psig (6 bar
(e)).
The maximum permissible air pressure, 90 psig
(6.2 bar (e)), must not be exceeded.
Blow any impurities out of the compressed air
hose before connecting it to the machine.
Select the correct dimension and length for the
compressed air hose. For hose lengths up to 100
feet (30 meters), a hose with a minimum internal
diameter of
3
" (19 mm) should be used. If the
4
hose length is between 100 and 330 feet (30 and
100 meters), a hose with a minimum internal
diameter of 1" (25 mm) should be used.