Rated
No.
Hoist Model
Capacity
Chain
No.
(kg)
Falls
ML250KS-E
ML250K-E
250
ML250KR-E
ML500KS-E
ML500K-E
500
ML500KR-E
ML1000KS-E
980
ML1000K-E
HL1000K-E
1000
HL1000KR-E
HL1500K-E
1500
HL2000K-E
2000
HL3000K-E
3000
HL4500K-E
4500
HL6000K-E
6000
* Sound measurements have been made in accordance with ISO 11201, ISO 3744-3746 and ISO 4871
test specifications for sound from pneumatic equipment. Readings shown are based on the average noise
level of each hoist configuration, proportionate to the utilized time in a regular cycle.
* Lpc (Peak Sound Pressure) does not exceed 130 dB.
* Performance based on 6,3 bar operating pressure.
Prior to installing the hoist, carefully inspect it for possible shipping damage.
Hoists are supplied fully lubricated from the factory.
Lubricate load chain before initial hoist operation.
Owners and users are advised to examine specific, local or other regulations which may
apply to a particular type of use of this product before installing or putting hoist to use.
A falling load can cause injury or death. Before installing, read "SAFE OPERATING
INSTRUCTIONS".

SPECIFICATIONS

Sound
Air Flow
Pressure
m³/min
Level
dBA
1,27
1
1,98
1,27
1
90
1,98
2
1,27
2
1
1,98
87
2
3
4

INSTALLATION

CAUTION
WARNING
Speed with
Speed with
Sound
Rated Load
No Load
Power
m/m
Level
dBA
up
down
up
12,2
27,4
21
30,8
35,7
52
7,9
11,6
12,8
6,7
20,1
13
100
16,8
29,6
32
4,0
6,1
6,4
3,4
10,0
6,7
8,5
14,9
16
7,9
11,3
12,2
4,9
7,9
8,5
97
4
5,5
6,1
2,4
4
4,3
1,4
3
3,2
1
2,3
2,6
4
Hook
Mount
Overload
Hoist
nominal
Weight
m/m
limit
3 m (10 ft)
kg
lift
down
kg
16
30
9,1
21,8
10
- - -
18
4,6
4,9
27,7
9
7,9
1250
38,1
4,9
1875
4
56,6
2500
2,4
58,5
3750
2
87,5
5625
1,5
112,5
7500

Werbung