Herunterladen Diese Seite drucken

Kessebohmer ScreenMotion Revolution 720 Montageanleitung Seite 26

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Customer-specific lifting limit
Saving Auto Memory positions
Overriding the upper lifting limit
To override the upper lifting limit, move the SME up to the position whre it stops. Press the key "S/M" six time followed by the "Up" key one
time. The column moves now up to the maximum lifting psition at half speed as long as you keep the "Up" key pressed.
As soon as the fitting reaches a position that is below the saved lifting limit ist is reactivated even if it was previously overridden.
To restore the factory setting or any other desired position move the fitting to the maxium lifting position an save the lifting limit
!
anew. (See above)
889012121 U76 Page 26 of 29
This function allows you to limit the height of the upward
Up
movement of the fitting. The SME is pre-adjusted to reach
the maximum lifting position by the manufacturer. The
Down
U U
customer-specific lifting limit is only possible with the free-
S/M
!
standing version. It is not feasible for the "installation in
furniture" version.
If you want the fitting to stop at a position lower than the
maximum lifting position move it to the desired position by
means of the arrow keys "Up" and "Down". Now press the
key "S/M" three times followed by pressing the "Up" key
one time.
This position is now saved which the control unit will
confirm with an acoustic signal. The SME can now only be
moved up to this position.
Down Up
There are 3 keys (M1;M2;M3) which can be assigned to
Left
Right
defined memory positions. These positions can refer to
U U
lifting or turning movements.
S/M
M1
Move the fitting by means of the arrow keys "Up" or "Down"
M2
M3
to the desired lifting position and turn the screen by means
of the keys "Turn TV left" or "Turn TV right" to the desired
position. Then press the "S/M" key three times. Afterwards
press immediately one of the memory keys (M1;M2;M3) to
save the current position. The control unit will confirm the
successful storage by emitting an acoustic signal.
The memory positions can be overwritten at any time by
saving a new position to a previously assigned key. To do
!
so the memory position must not be cancelled separately.
Simply move the fitting to the desired position and save the
new position.

Werbung

loading

Verwandte Produkte für Kessebohmer ScreenMotion Revolution 720

Diese Anleitung auch für:

Screenmotion revolution 870