5.

Operation

A
B
5.1.

Start sauna operation

FIRE HAZARD!
There is a danger of fire while the sauna stove is on operation. Always check the control
system before starting up, and ensure that no flammable objects are left on the sauna
stove.
1.
Activate the control system at the master switch (B).
2.
Turn the temperature controller (D) to the right to set the desired temperature.
The LED (A) flashes when the sauna is in operation.
The heat source is activated. The sauna is ready for use after the warm-up period.
'
Adjust sauna temperature - see section 6.1.
5.2.

End sauna operation

1.
Disconnect the control system at the master switch (B).
The operating LED (A) goes out.
6.

Individual settings

6.1.

Adjust sauna temperature

Use the controller (D) to adjust the temperature in the sauna.
The normal sauna temperature is 85 °C - 95 °C.
The middle setting on the temperature controller corresponds to a temperature of
approx. 80 °C.
In IR mode, the wall temperature ranges from 50 °C to a maximum of 60 °C. This creates
a sauna temperature of approx. 35 °C - 40 °C.
The cabin temperature indicated in IR mode relates to an ambient temperature of 20 °C
- 25 °C.
The temperature sensor is placed in the current of hot air above the sauna stove.
There is an unavoidable difference in temperature between the sensor and the control
system. This is why there is no scale on the sauna-temperature controller (D).
1.
Activate the control system at the master switch (B).
2.
Turn the temperature controller (D) to the right as far as it will go. The heat source brings the sauna
cabin up to its maximum temperature.
.
In IR mode, the wall temperature ranges from 50 °C to a maximum of 60 °C.
3.
Determine your most comfortable preferred temperature while the sauna cabin is warming up.
4.
Slowly turn the temperature controller (D) on the control unit anticlockwise, until you hear a faint
"click". The temperature is now set to your preferred level.
5.
Mark the position of your preferred controller setting on the housing.
PAGE 18
Element/Button:
C
D
Description:
A
LED operation
B
Master switch
C
Button Light
D
Controller Sauna temperature