Herunterladen Inhalt Inhalt Diese Seite drucken

Maintenance And Cleaning - Oase AquaMax Eco Twin 20000 Gebrauchsanleitung

Vorschau ausblenden Andere Handbücher für AquaMax Eco Twin 20000:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Maintenance and cleaning

Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures:
Electrical units and installations with a rated voltage of U > 12 V AC or U >30 V DC located in the water:
Isolate the units and installations (switch off and disconnect from the power supply) before reaching into
the water.
Isolate the unit before starting any work.
Secure the unit to prevent unintentional switching on.
Cleaning the unit
Note!
Recommendation on regular cleaning:
Clean the pump as required but at least twice a year.
Never use aggressive cleaning agents or chemical solutions. These could attack the housing surface or impair the
function.
Recommended cleaning agent for removing stubborn limescale deposits:
– Pump cleaning agent PumpClean from OASE.
– Vinegar- and chlorine-free household cleaning agent.
After cleaning, thoroughly rinse all parts in clean water.
Cleaning the pump
Remove pump from the bottom strainer casing:
F
Remove hoses from the unit. Open the clips (6) and remove the strainer top casing.
Undo both union nuts (8) and remove the Y distributor (9).
Release the clamps (4) and take pumps out of the bottom strainer casing.
Note for the assembly: For secure pump fastening, ensure that the clamps (4) engage.
Open the pump housing:
G
Remove screws and the pump housing.
Clean the pump housing, impeller and flat seal under clean water using a brush.
Check parts for damage and replace, if necessary.
Reassemble in the reverse order.
- EN -
15

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Aquamax eco twin 30000

Inhaltsverzeichnis