■ It is possible to save the list in ".csv" (Comma Separated Values)
format to then be imported into a spreadsheet program (i.e. Mi-
crosoft® Excel); as follows:
- open the programme ("browser") to navigate the Web and
type the indicated address in the webgate navigation bar
(refer to Chapter "Using the control system - preliminary opera-
tions") followed by/log/report.csv ; take the following as an
example:
http://192.168.0.100/log/report.csv

EXAMINATION OF MULTIPLE CONTROL SYSTEMS

■ In the instance where multiple control systems are connected
to the same network (LAN or WLAN/Wi-Fi), it is possible to check
operation by clicking on the corresponding key, presented in the
bottom part of the display.

OPERATION IN "MONITOR" MODE

With the sauna module, if the keypad activation procedure is not
carried out, it is possible to use the control system as a tool to check
Sasha operation, without activating the various programmes; it is
possible to stop the programme under way and/or manage opera-
tion of lights.

TROUBLESHOOTING

■ The remote control system cannot be activated and does
not respond to commands.
- Check that Sasha is on.
- Check that the switch inside the electrical box is in the ON posi-
tion (✐ 7 of the present manual).
- Check the configuration of the network connection parameters
(refer to the Chapter "Web-based access configuration").
- Check the status of the "STAT" and/or "COM1" LED present on the
control system (see also Chapter "Checks"): where they remain on
permanently, it is probable, that errors have been identified.
- press the "Enter" key: a list of data, separated by commas, will
appear. At this stage, from the"File" menu of the programme
("browser"), select the "Save As" command to save the report.
csv file in the selected location.
- import the file to the spreadsheet program.
■ To exit the "LOG" mode, click once again on the button to the
right of the term.
The relative welcome display will appear, from here, it is possible
to access the various modules connected to the control system
in question.
■ To move onto another control system, click on the correspond-
ing key.
With the hammam module, as there is no activation procedure,
the "monitor" mode coincides with the operation mode.
To exclude the possibility of controlling the appliance from the
keypad, you must lock the keypad (see the user manual, Chapter
"Functions associated with keypad lock") and therefore, use the re-
mote control system.
Try switching off the system and then on again; if this does not
work, reset the system, as described in the Paragraph "Password
for access to web not available or misplaced".
■ It is not possible to connect the control system to the net-
work.
- Check that Sasha is on.
- Check that the switch inside the electrical box is in the ON posi-
tion (✐ 7 of the present manual).
37
■ To delete the data saved, click on the
key to the left of the term.