Herunterladen Inhalt Inhalt Diese Seite drucken

Panasonic CS-Z25TKEA Bedienungsanleitung Seite 22

Vorschau ausblenden Andere Handbücher für CS-Z25TKEA:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

Troubleshooting
When...
■ Use when remote control is a malfunction occurs
AUTO
OFF/ON
■ Conducting a seasonal inspection after extended non-use
• Check that there is no obstruction around the air inlet and outlet vents.
• Use Auto OFF/ON button to select COOL/HEAT operation. After 15 minutes of operation, it
is normal to have the following temperature difference between the air inlet and outlet vents:
COOL: ≥ 8 °C / 14.4 °F
■ The units are not going to be used for a long period of time
• Activate HEAT mode for 2~3 hours to remove moisture left in the internal parts thoroughly to
prevent mould growth.
• Turn off the power supply and unplug.
NON SERVICEABLE CRITERIAS
TURN OFF THE POWER SUPPLY AND UNPLUG then please consult an authorised
dealer when in following conditions:
• Abnormal noise during operation.
• Water/foreign particles have entered the remote control.
• Water leaks from Indoor unit.
• Circuit breaker switches off frequently.
• Power cord becomes unnaturally warm.
• Switches or buttons are not functioning properly.
22
1. Raise the front panel.
2. Press the button once to use in AUTO mode.
3. Press and hold the button until you hear 1 beep, then release to use in
forced COOL mode.
4. Repeat step 3. Press and hold the button until you hear 3 beeps, then
release to use in forced HEAT mode.
5. Press the button again to turn off.
HEAT: ≥ 14 °C / 25.2 °F

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis