11. Take the left evacuation unit, pass it
around the motor module, hang it in
above, lower it and fix it in place with
two M5 screws.
Complete the electrical connection:
X1 = Controls
X2 = LED power display
Pay attention to the writing on the ca-
bles!
12. Take the right evacuation unit, pass it
around the motor module, hang it in
above, lower it and fix it in place
with two M5 screws.
12
13. Insert the light panel on the motor
module and connect up the sensor
and the sensor cable. Connect the
light fittings up to the LED spot-
lights. Hang the safety loop on the
light panel.
Now push the light panel upwards
until the four magnets connect, en-
suring that the cables are fed into
the motor module and do not be-
come clamped. Caution: Ensure
when doing so that the glass edges
do not cause any problems!
14. Carry out a functional test!