Functional elements
1 Counter sleeve
2 Adjusting nut
3 Anvil bolt
4 Clamping for support
5 Bracing support
6 Measuring bolt
7 Throats
8 Handle
1
9 Confirmation key for withdrawal
10 Control unit with display
2
10
3
4
9
5
6
8
7
Programming
Password may be required!
B
A
Selecting the unit
mm/inch
Selection of resolution
0.0001/0.001 mm
0.000005/0.00005 inch
CAL.
Insert the master value
PRESET-value
Insert the multiplier
2
1
Further operational functions can only be carried out or activated when
connected to a PC.
Please refer to the separate operating instructions for this purpose!
Operation
Description
The Digitalpassameter is a measuring device for comparative measurement with an
inductive measuring system with extended measuring range and support point
correction.
The detached handle (8) is used to reduce the hand heat transfer and allows easier
positioning of the measuring device on the specimen thanks to the integrated venting
knob (9). Safe handling is possible thanks to the anvil bolt (3) resting at the top and the
additional centring support (5).
Application area
Passameters are adjustable snap gauges which are mostly used for measuring and
testing of round-cut and milled parts. They replace a large number of fixed gauges whilst
this device also has the advantage of a number display if there are deviations to the
preset value.
Handling during measuring
Safe handling is the most important basis to avoid measuring errors. The measuring
areas and the specimen have to be cleaned thoroughly prior to every measurement.
Setting the device to the nominal dimension with gauge blocks, gauges or a selected
specimen. Setting should only ever be done in reference to the electric zero position of
the inductive measuring system; for this purpose an existing zero compensation has to
be deleted by long pressing of the
key. First the counter sleeve (1) has to be
PRG
PRG
loosened. Then the anvil bolt (3) has to moved axially by turning the adjusting nut (2)
until the display (10) shows approx. zero. It may be necessary to readjust the counter
sleeve (1) several times for this purpose. Once the desired position has been achieved, it
is fixed by tightening the counter sleeve (1) and should be checked for reproducibility by
indicating repeatedly.
Display unit can
Finally, a short pressing of the
key allows setting the
B1
be rotated
previously programmed value.To insert and remove the
through 360°
specimen, the measuring bolt (5) has to be pulled back by
applying pressure on the digimatic indicator (9). The use of
the digimatic indicator (9) secures an even measuring
B2
force. Please avoid impact type loads and use of force.
The combination of the overhead anvil bolt (2) and the
adjustable centring support (5) allows the safe positioning
of the measuring device onto the specimen and the user
B3
does not have to tare it. To adjust the centring support (5),
the clamping screw (4) is loosened and the support (5) is
moved in such a way, that the measuring area touches the
specimen in the centre at the highest point. This position
has to be fixed by the clamping screw (4).
The adjoining image shows the control elements
A2
and the direction of motion.
A = Digimatic indicator
B = Anvil bolt adjustment
Programming
Continuation of the programming
2
Activation und mode setting for dynamic measurement
1
Activation of classification
Selection of a
tolerance display
1. on/off
2. Programming the
3. Programming the
lower tolerance group
upper tolerance group
Activation of tolerance-LED
LED oFF = off
LED 01 sec...10 sec = display
4
time in seconds
3
Control unit
Display and control unit
1
2
1 Interface protective cover
2 Display range for bargraph
3
3 Status LED
4 Measuring value/
functional level
5 Unit
4
6 Second allocation
7 Operating key
8 Operating key
5
9 Battery lid
ENTER
10 Operating key
6
7
10
9 8
Switch on
Switch off
Pressing the key
Press
key for a long moment
The auto-power off time can be
adjusted via the PC software
PRG
Measuring mode
Data transfer with output
Access
A1
Programming
Tolerance position for tolerance LEDs
Short press on key
Menu
Start/stop of the dynamic measurement
Permanent measuring value trans-
Delete Zero
Long press on key
mission for measuring value changes
adjustment
Mode is left by pressing any key.
Programming
Mode
Change
Change
Short press on key
Blinking display
Blinking display
Leave
---
Long press on key
programming menu
Programming
Continuation of the programming
4
Activation/deactivation of programming-passcode
3
(with input of passcode)
Activation/deactivation of calibration-passcode
(with input of passcode)
Deactivation/activation
of Auto-Power-Off_Time
Deactivation/activation
B
A
Operating instructions
Digitalpassameter
Feinmess Suhl GmbH
Pfütschbergstraße 11
D-98527 Suhl
Fon: +49 (0) 3681 / 381-0
Fax: +49 (0) 3681 / 381-105
info@feinmess-suhl.de
www.feinmess-suhl.de
PRG
Zero adjustment
Meas. value is set on
PRESET-value
SD1 switch off
Confirm
Blinking display
---
Interface/Technical data
Interface connection
In addition to data transmission via a
cable-connected interface connection, it
is also possible to transmit wireless with
a radio module.
Turning the display unit allows setting a
favourable position for insertion. After
loosening the fitting screw of the interface
cover, the interface or radio module can be
used and fitted.
The measuring device is ready for transmission
after establishing a connection and completing the
installation of the necessary drivers and programmes.
The description of the interface protocols and interface
commands can be found in the separate operating
instructions which are supplied with the modules.
Battery change:
The blinking BAT-symbol in the display prompts you to change
the battery. All lithium type batteries for the 2032 series can be
used as replacements (installation dimensions: ø20 mm; thickness
3,2 mm) with 3 V operating voltage. Turning the display unit allows
setting a favourable position for removal. The battery holder can be removed
after loosening the fitting screws. When inserting the new battery, please make sure you
assign the poles correctly. The plus pole of the battery has to point downwards to the plus
symbol of the holder. The measuring device is ready for use again after inserting and
securing with the fitting screws.
(with input of Auto-
Power-Off_Time)
Technical data
Adjustment range:
Measuring range/indicator path:
of key sounds
Resolution:
Measuring area diameter
Measuring force:
Display / Digit height:
Cancelling the
Functions:
programming menu
Data interface:
Battery:
Operating duration:
Protection class:
Right to make changes due to technical advancements is reserved.
Juli 2016
76 3902
Radio module
Interface
Interface
IBRit-rf1-III
Module
cover
Triple-I-USB
Battery holder with
battery CR 2032
30 mm
4 mm
0,0001 mm/0,001 mm
0.000005 inch/0.00005 inch
10 mm
12-18 N
7 digits / 10 mm
Bargraph, Max/Min/Max-Min, PRESET,
Tolerance mode with LED display
Unit change possible mm/inch
USB/RS232 / Radio rf1
CR2032
approx. 2000 h