    Specification & Performance Guideline Performance Curve Maintenance & Troubleshooting Inspection & Maintenance Troubleshooting Installation Instructions (abbreviated) - French Installation Instructions (abbreviated) - Spanish Installation Instructions (abbreviated) - German For Your Records Limited Warranty Doc No:SM-137 Iss. C 13.02.13 Marlec Eng Co Ltd...
  • Seite 4: Introduction

    Note: There are other Rutland Windchargers designed for permanent installations on land - contact Marlec or visit www.marlec.co.uk to find out more. Rutland 914i Profile & Dimensions Fig 1 Doc No:SM-137 Iss.
  • Seite 5: General Guidelines And Warnings

    We recommend the use of Marlec charge regulator that includes a shutdown switch. Choose a calm day to install the equipment and consider other safety aspects.
  • Seite 6: Check You Have Received

    1 x 6mm Allen key 1 x 2-way terminal block 2 x M10 buttoncap screws 2 x shakeproof washers In the event of loss or damage, consult your dealer or the manufacturer. Doc No:SM-137 Iss. C 13.02.13 Marlec Eng Co Ltd...
  • Seite 7: Other Items

    Short section of stainless steel tube to adapt into your own mounting design. Voltmeter & Ammeter Exploded View of The Rutland 914i Nacelle Dome Six Blades with Twenty Four Tail fin Nose Cone With Three Screws Post Adaptor Generator Hub Doc No:SM-137 Iss. C 13.02.13 Marlec Eng Co Ltd...
  • Seite 8: Assembly & Installation

    48.5 mm for the top 0.6m minimum to (i) prevent accidental damage and (ii) meet warranty conditions. 3. Mount a charge regulator, from the Marlec range, to a suitable vertical surface and close to the battery. Follow instructions supplied with the charge regulator.
  • Seite 9: Tower Preparation

    3. Drill two holes 10.5mm in diameter on centre-punch positions. Note :Use metric measurements for this operation Note: When using Rutland 914i Mounting Kit , items 2 and 3 can be ignored as Marlec supplied poles are pre-drilled. Blade Assembly (Fig.3) Fig. 3 1.
  • Seite 10: Tail And Nose Assembly

    4. Fit the plastic nose dome in position on the front of the generator hub and secure in place with the three nylon screws provided. 5. You may now mount the Rutland 914i on to the tower if you have not already done so. Doc No:SM-137 Iss. C 13.02.13 Marlec Eng Co Ltd...
  • Seite 11: Electrical Connection & Fitting To The Tower

    Take care to avoid all moving parts when raising and lowering the wind generator. When raised, secure the structure firmly in an upright position. Caution-The performance of your Windcharger will be impaired if the pole is not vertical. Doc No:SM-137 Iss. C 13.02.13 Marlec Eng Co Ltd...
  • Seite 12: Typical Wiring Diagrams For The Rutland 914I Windcharger

    Typical Wiring Scheme For A Single Battery Bank Typical Wiring Scheme For Single or Dual Battery Banks HRDi Charge Regulator Solar Panel Maximum 12/24 V 160 Watts In-Line Fuse Second battery optional Doc No:SM-137 Iss. C 13.02.13 Marlec Eng Co Ltd...
  • Seite 13: Siting The Windcharger

    It is therefore essential that the wind generator should be located in an area as free as possible from disturbed wind flow. Fig. 4 AREA OF TURBULENCE WIND DIRECTION Doc No:SM-137 Iss. C 13.02.13 Marlec Eng Co Ltd...
  • Seite 14: Mounting The Windcharger

    Fig. 8 the wind turbine is mounted. River Boats (Fig.8) A pivot pole is ideal for riverboats as the Windcharger can easily be raised and lowered. Doc No:SM-137 Iss. C 13.02.13 Marlec Eng Co Ltd...
  • Seite 15: Land Based Systems

    Two forms of pivot tower are suggested in Figs 9 & 10. A base-hinged 6.4m tall Land Tower Kit (Part No: CA-12/08) and Rigging Kit (Part No:CA- 12/07) are available from Marlec. Doc No:SM-137 Iss. C 13.02.13 Marlec Eng Co Ltd...
  • Seite 16: Further System Requirements

    Total = 24v We strongly recommend that one of the voltage 60Ah 14 40Wh regulators available from Marlec is fitted to prevent batteries becoming overcharged in strong winds and is essential with gel/sealed batteries. 60Ah 60Ah Batteries may be linked as shown in the figures 10 and 11.
  • Seite 17: Specification & Performance Guideline Performance Curve

    Wind speeds are those flowing across the turbine of the Windcharger and may not reflect those measured at mast top or those reported by the Met. Office. Doc No:SM-137 Iss. C 13.02.13 Marlec Eng Co Ltd...
  • Seite 18: Maintenance & Troubleshooting

    Should you wish to take the unit out of service for an extended period it is recommend that the unit be removed from the mounting and stored in a dry location or covered. Doc No:SM-137 Iss. C 13.02.13 Marlec Eng Co Ltd...
  • Seite 19: Troubleshooting

    Set the digital multimeter to DC Amps and measure power between the wind generator + and the battery +. If a reading is measured, providing there is sufficient wind, then the regulator is faulty. Doc No:SM-137 Iss. C 13.02.13 Marlec Eng Co Ltd...
  • Seite 20 If the above checks have identified a need for spare parts or failed to identify the problem you should contact Marlec who can advise you of your nearest distributor in their world wide network. In the first instance we recommend that you contact the company from whom the product was originally purchased.
  • Seite 21: Installation Instructions (Abbreviated) - French

    NB : il existe d’autres modèles d’éoliennes conçues pour une installation terrestre permanente. Venez les découvrir sur notre site www.marlec.co.uk Informations générales et mises en garde Le diamètre externe du mât ne doit pas être supérieur à...
  • Seite 22 1 x Nacelle 6 x Pâles et 24 x Vis 10 x 25mm auto taraudeuses 1 x Adapteur de poteau 1 x Corps d’éolienne 1 x Cône avant+ 3 vis de fixation Doc No:SM-137 Iss. C 13.02.13 Marlec Eng Co Ltd...
  • Seite 23 50 derniers centimètres, pour prévenir tout risque de dégâts et effectuer un montage conforme aux exigences de la garantie. 3. Monter un régulateur, choisi dans la gamme proposée par Marlec, sur un plan vertical et à proximité des batteries. Suivre les instructions de montage fournies avec le régulateur.
  • Seite 24: Installation Instructions (Abbreviated) - Spanish

    Evite dejar la turbina atada durante mucho tiempo; le recomendamos que cubra la turbina para protegerla de la intemperie o retírela y guárdela en un lugar seco. Le recomendamos que utilice el regulador de carga Marlec que incluye un interruptor de desconexión.
  • Seite 25 1 x Cubierta 6 x paletas y 24 x 10x25 torniillos 1 x Adaptador del 1 x Eje del generador 1 x Cono de nariz y 3 x tornillos Doc No:SM-137 Iss. C 13.02.13 Marlec Eng Co Ltd...
  • Seite 26 48,5 mm para los primeros 0,6 mm cómo mínimo para (i) evitar daños accidentales y (ii) cumplir con las condiciones de la garantía. 3. Monte un regulador de carga, del rango Marlec, sobre una superficie vertical adecuada y cer- ca de la batería. Siga las instrucciones proporcionadas con el regulador de carga.
  • Seite 27: Installation Instructions (Abbreviated) - German

    Stromverbrauch für Haushaltsgeräte und auch für Navigationsgeräte etc. erforderlich ist. Anmerkung: Für weitere Windcharger von Rutland, welche für die dauerhafte Montage an Ort und Stelle entworfen wurden, treten Sie bitte mit Marlec in Kontakt oder besuchen Sie www.marlec.co.uk für weitere Informationen. Allgemeine Richtlinien & Gefahrenhinweise Die Mastmontage DARF den Außendurchmesser von 48.5mm, zumindest den Oberen von...
  • Seite 28 Im Zweifelsfall wenden Sie sich bitte an Ihren Fachhändler, an einen fachkundigen Elektroingenieur oder an den Hersteller. 1 x Haube 6 x Rotorblatter und 24 x Schrauben 1 x Nase und 3 x Schrauben 1 x Pfosten Adapter 1 x Generatornabe Doc No:SM-137 Iss. C 13.02.13 Marlec Eng Co Ltd...
  • Seite 29 (i)einen Nebenschaden zu vermeiden und (ii) die Bedingungen der Garantie zu erfüllen. 3. Montieren sie eines der Aufladekontrollgeräte von der Firma Marlec an eine geeignete senkrechte Oberfläche und in der Nähe der Batterie. Befolgen Sie die Anleitung, die mit dem Aufladekontrollgerät mitgeliefert wurde.
  • Seite 30: For Your Records

    Rutland 914i Windcharger Installation & Operation For Your Records For your future reference we recommend you note the following: Serial Number: Date of Purchase: Date of Installation: Type of Regulator: Doc No:SM-137 Iss. C 13.02.13 Marlec Eng Co Ltd...
  • Seite 31: Limited Warranty

    Marlec's obligation in this respect is limited to replacing parts, which have been promptly reported to the seller and are in the seller’s opinion defective and are so found by Marlec upon inspection. A valid proof of purchase will be required if making a warranty claim.
  • Seite 32 Solar power that works with your Rutland Windcharger Solar power to keep batteries topped up on-board Energy saving solar panels for your home Marlec Engineering Co Ltd Rutland House, Trevithick Road, Corby, NN17 5XY Tel:+44 (0)1536 201588 Fax:+44 (0)1536 400211 sales@marlec.co.uk www.marlec.co.uk...

Inhaltsverzeichnis