TECHNICAL DATA

DS12
Max. working area
90 m
2
Air flow step 1
256 m
/hour
3
Air flow step 2
-
Dehumidifying at 20°C and 70% r.h.
6.11/day
Dehumidifying at 35°C and 80% r.h.
11.11/day
Power at 35°C and 80% r.h.
220W/hour
Tank volume
10.4 litres
Cooling medium, freon-free
R134A
Dimensions in mm., L x B x H
343 x 406 x 527
Weight
22 kg.
Noise level in decibels
38 dB
PROBLEM
SOLUTION
Dehumidifier does not start
-
Check that dehumidifier is connected to electricity and that fuse has not gone
-
If the warning light is on, check that the water reservoir is empty and correctly placed in the dehumidifier.
Check that float is free
-
Check that hygrostat is working. Dehumidifier should start when hygrostat is in Maximum position
Does not dehumidify
-
Check that fan is spinning
-
Check that air can flow freely through the dehumidifier. Front grid and air filter should be clean and dehumidifier should stand
20-30cm from wall
-
Listen for sound of compression, but bear in mind that the dehumidifier may be in a dehumidifying cycle, when the compression stops. Wait initially for about 35
minutes.
-
Check that a thick coating of ice has not formed on the cooling coils.
High noise level
-
Increase distance between dehumidifier and surrounding surfaces
-
Cooling coils may be in contact with one another and cause vibration. Disconnect dehumidifier from electricity and separate coils
Ice formation on cooling coils
-
Remove air filter at rear of dehumidifier and check that no dust or fluff is obstructing passage of air through machine
-
Timer which controls defrosting may be broken, in which case compression will not stop regularly
No water enters reservoir
-
Check for obstruction to drip-tray above water reservoir
Does not turn off when water
-
It is important that the float moves freely in the water reservoir. If it does not, it will not respond to water levels and prevent dehumidifier from stopping
reservoir is full
If none of the above works, you should contact your nearest retailer for checking and possible overhaul of dehumidifier
02
DS15
DS28
DS36
TDR36S
100 m
140 m
190 m
250 m
2
2
2
2
255 m
/hour
190 m
/hour
197 m
/hour
197 m
/hour
3
3
3
3
520 m
3
/hour
336 m
3
/hour
347 m
3
/hour
347 m
3
/hour
6.71/day
10.41/day
13.21/day
-
12.01 day
17.51/day
20.81/day
24.3L
240 W/hour
460 W/hour
510 W/hour
290 W/hour
10.4 litres
10.4 litres
10.4 litres
10.4 litres
R134A
R134A
R134A
R134A
343 x 406 x 527
343 x 406 x 527
343 x 406 x 527
368 x 435 x 605
22 kg.
24 kg.
26 kg.
23,5 kg.
38-50 dB
38-50 dB
38-50 dB
38-48 dB
Wood's, the World's
ED50
leading dehumidifiers
230 m
2
Wood's dehumidifier products have
129 m
/hour
3
been known as market leaders for
296 m
3
/hour
many years. Their dehumidifiers are
21.11/day
suitable for use in the most demanding
climates, where dehumidifying capacity
33.21/day
is good even at lower temperatures
850 W/hour
and humidity levels. They are used with
10.4 litres
good results in premises that become
R407C
damp such as cellars, garages or
summer-houses. They are also excellent
343 x 406 x 527
for drying washing, attics, pool rooms
28 kg.
and laundry. being efficient and low
38-58 dB
on energy consumption. Does not wear
out clothes.
The amount of humidity that the
dehumidifier removes depends on
temperature, humidity level and
placement. External weather conditions
may also affect the performance of the
dehumidifier.
In cold weather the relative humidity
decreases and thus the extraction
of humidity from the air by the
dehumidifier is reduced. Therefore the
dehumidifier is suitable for use in the
temperature range +5˚C to +35˚C.
Wood's dehumidifiers are safe in
operation and intended for continuous
use over many years. That is why
Wood's offers a 5-year guarantee on the
compressor and 2-year guarantee on
other components.
Operating Instructions
excessive air humidity – a
danger
dehumidifier should be fixed
Condensation occurs when water
in place. It is compulsory to check
vapour in the air comes into contact
and respect your local bathroom
with a cold roof, window or wall.
regulations before use.
When water vapour is cooled down,
condensation occurs, and water-drops
using the dehumidifier
are formed. In high air humidity, the air
If the dehumidifier is transported
may get musty and mould is formed,
horizontally, oil may have run out of
causing damage to a house and its
the compressor and into the closed
furnishings. This environment may
piping system. In such a case, let
even cause illness for the residents,
the dehumidifier stand for a few
since mites and other creatures thrive
hours before being used. It is very
in a damp environment. A dehumidifier
with high performance creates a good,
important that the oil runs back into the
compressor, otherwise the dehumidifier
healthy humidity level, and for greatest
may be seriously damaged.
efficiency the doors and windows of
rooms that are being dehumidified
1. Check that the water reservoir is correctly
should be kept closed. Removes odours,
placed and the float moves freely in the
dries wood and removes moisture from
reservoir. See the section on the Float.
sportsware outdoors equipment.
2. Connect the dehumidifier to an earthed
A dehumidifier may be used in cellars,
power source.
washrooms, garages, crawl spaces,
caravans, summer-houses and on
3. Select fan speed. (not DS12)
boats. If the humidifier is kept in colder
4. Set the desired humidity level by means
environments, you should study the
of the hygrostat. See the section on the
Hints at the end of the manual.
Hygrostat.
Placement of dehumidifier
Wood's dehumidifiers are easy to move
around, all you need to have is a power
source for 220/240V, but bear in mind
should wait three minutes before
the following:
restarting, so that the built-in
automatic functions are deactivated.
- The dehumidifier should not be placed
near radiators or other heat sources
or exposed to direct sunlight, as it will
reduce performance.
- It is beneficial to use a radiator or
heating fan to keep the temperature
above +5˚C.
- The dehumidifier should stand at least
25cm from a wall or other obstruction,
for maximum air flow.
- Ideal is to put it in the center
of the room / area.
GB
note: When placed in a
shower or bathing area, the
note: When the
dehumidifier is turned off, you
03

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Tdr36sDs15Ds12Ds36Ed50

Inhaltsverzeichnis