Herunterladen Inhalt Inhalt Diese Seite drucken

Installation And Connection; Maintenance And Cleaning; Technical Data - Renkforce 751560 Bedienungsanleitung

Dualer bewegungsmelder
Vorschau ausblenden Andere Handbücher für 751560:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Installation and connection

a) Installation
Please follow the chapter "Safety Instructions".
Important!
The motion detector may not be connected to the mains voltage. It is only
suitable for an operating voltage of 12 V/DC.
The relay is also not suitable for connecting to the mains voltage. Only a
maximum voltage of 24 V/DC and a maximum current of 100 mA must be
connected.
• The motion detector must only be connected in a de-energised state.
• Only mount the motion detector with the wall holder to a solid base, e.g. masonry.
Use screws and, if necessary, screw anchors that are suitable for the surface. We
recommend a mounting height of 2 to 3 m.
• The motion detector must be installed such that it is out of the reach of children.
• Paying attention to the correct position of the wall holder, mount the same
using two suitable screws, and if required, wall plugs. The arrow in the
image on the right marked "top".
Caution!
Pay attention when drilling and tightening the screws that no ca-
bles or pipes are damaged!
• Remove the circuit board of the motion detector from the
housing after removing the screw (4).
• There is no hole yet in the back of the housing for cable lead-
through.
Drill a corresponding hole (A) in the imprint (9); the diameter
depends on the connection cable used.
• Mount the back of the housing to the wall holder using one of
the screws provided.
It is helpful to either drill a little hole or to penetrate the plastic
with a pointed object in this spot (B).
Make sure that the hole does not get too big; otherwise, the
back of the housing cannot be mounted on the wall holder.
• Replace the circuit board and secure it with the screw (4) that
you removed earlier.
• Guide the connection cable through the hole drilled earlier (A).
b) Connection
Screw terminals "DC12 V +/-"
Connect these two screw terminals with the voltage/power supply, e.g. from a suitable
alarm system. Pay attention to the correct polarity.
Screw terminals "TAMPER N.C."
This is a potential-free tamper contact. When opening the housing, the contact is in-
terrupted so that a connected alarm system can trigger an alarm.
The maximum contact rating is 12 V/DC, 50 mA.
Screw terminals "ALARM"
This is a potential-free relay contact. Using the jumper "MODE P/S" (2), the function
can be toggled between operation as NC contact (opener) and NO contact (closer).
The relay contact is triggered when the motion detector detects a heat change in the
detection range.
The maximum contact rating is 24 V/DC, 100 mA.
c) Setting jumpers
Jumper "LED ON/OFF" (1)
Position "ON"
The LED is illuminated when a movement was detected in the
detection range or when the housing is opened and the tamper
contact is triggered.
Position "OFF"
The LED is on continuously. This can be used when when the
activation process (when a heat change is detected in the de-
tection range) of the motion detector should not be visible in the
dark.
Jumper "MODE P/S" (2)
Position "S"
The motion detector is activated immediately in the event of a
heat change.
Position "P"
The motion detector is only activated if a second heat change
is detected within 10 seconds inside the detection range. This
setting can be used, for example, when the motion detector is
erroneously activated due to the existing environmental condi-
tions.
Jumper "ALARM" (3)
Position "N.C."
The screw terminals "ALARM" function as NC contact (open-
er). The contact is opened when the motion detector detect a
heat change in the detection range.
Position "N.O."
The screw terminals "ALARM" function as NO contact (closer).
The contact is closed when the motion detector detect a heat
change in the detection range.
d) Startup
• When you have connected all cables and made all settings,
place the front of the housing while paying attention to its
correct position and screw it tight.
• Align the motion detector to the desired detection range.
• Switch on the voltage/power supply.
Then, it will take about 2 minutes until the PIR sensor have adjusted to the ambient
temperature of the detection area.
During this time, the red LED (5) flashes if it is switched on ("ON") via the
jumper "LED ON/OFF" (1).
After these 2 minutes, the motion detector is ready for operation and switch-
es the relay when it detects heat changes in the detection range.

Maintenance and Cleaning

The product is maintenance-free. Repair or maintenance work must be carried out
by a specialist.
You can use a clean, dry, soft cloth for cleaning. Do not press too hard on the lens of
the PIR sensor.
Do not use aggressive, chemical or scouring cleaning agents, as this may lead to dis-
colouration or changes in the material on the surface.
Disposal
The product must not be disposed of in the household waste.
Dispose of the product at the end of its serviceable life in accordance with
the current statutory requirements; e.g. return it to any suitable collection
point.

Technical Data

Operating voltage..........................................12 V/DC
Current consumption ....................................approx. 15 mA
Contact rating ................................................Connection „ALARM": max. 24 V/DC, 100 mA
..........................................................................Connection "TAMP N.C.": max. 12 V/DC, 50 mA
Contact type ................................................... Connection "ALARM": Relay: function can
..........................................................................Connection "TAMP N.C.": Button, NC contact
..........................................................................(opener)
Switch duration (connection "ALARM") .. approx. 2 - 3 seconds (when a heat change
PIR detection angle ......................................85° (horizontal)
PIR range ........................................................ max. 12 m (see chapter "Function of the mo-
Ambient conditions ....................................... Temperature -10 °C to +55 °C, air humidity
Dimensions (H x W x D)................................105 x 60 x 42 mm (without wall holder)
Weight .............................................................approx. 74 g
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent
the technical status at the time of printing.
© Copyright 2015 by Conrad Electronic SE.
be toggled between NC contact (opener)
and NO contact (closer)
is detected in the detection range)
tion detector")
max. 90%, not condensing

Quicklinks ausblenden: