Status-LED
Meaning
Perma-
Error in alarm
nently lit
zone 1 or 2
Sensor was
triggered
Alarm system
not disarmed
after alarm
48
Explanation
Error in alarm zone 1 or 2:
Check the sensor connections of alarm zones
1 or 2 and their sensors.
A sensor was triggered:
Check the connected sensors. Check if win-
dows or doors are opened where a door/
window detector (=magnetic contact) is con-
nected.
After the alarm system has triggered an alarm
and the acoustic signalling duration (= approx.
3 minutes) has passed, the alarm message is
stored and optically indicated by a permanent-
ly lit status LED.
In this case, check all sensors and the connec-
tion of alarm zones 1 and 2 to determine the
cause that triggered the alarm. Then disarm
the alarm system by setting the "mode selec-
tion switch" to "OFF".