Herunterladen Inhalt Inhalt Diese Seite drucken

Renkforce 751781 Bedienungsanleitung Seite 52

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Programming system security
70
71
72
5 - 10
76
00
Programming the door activity alarm
80
1
80
0
52
#
After the wrong code has been entered 10 times, the device
locks out access for 30 seconds.
#
After the wrong code has been entered 10 times, the device
switches contact (16) "DURESS" to ground. The device re-
mains in this state until user code 1 is entered and the # key
is pressed.
You can connect a suitable telephone dialler, a transistor
switch or similar device to this contact. Be sure to stay within
the loading specifications of this out put.
#
The number of times a wrong code can be entered can be
set to a value between 5 and 10. After the specified number
of wrong code entries, the device locks out access for 15 mi-
nutes. This lockout can be removed prematurely by entering
the master code.
#
Codes can be wrongly entered any number of times. No lock-
out period.
#
Acoustic signal after opening or closing of the connection
between the terminals (4(-)) ground and "DOOR SENS" (3).
#
No acoustic signal after opening or closing of the connection
between the terminals (4(-)) ground and "DOOR SENS" (3).