Herunterladen Inhalt Inhalt Diese Seite drucken

Renkforce 751781 Bedienungsanleitung Seite 43

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

1 & 2
Sabotage contact for 24 h alarm loops in alarm systems
3
Minus connection for green LED (-)
4
Plus connection for green LED (+)
5
Minus connection for red LED (-)
6
Plus connection for red LED (+)
7
Minus connection for red "AUX" LED (-) (middle LED)
8
Key alarm, NPN output, max. 24 V/DC, 100 mA
9
Input terminal of relay 2 for terminals 10 & 11
10
NO contact of relay 2, in a normal state this terminal is not connected to
terminal 9 (normally open)
11
NC contact of relay 2, in a normal state this terminal is connected to termi-
nal 9 (normally closed)
12
Output 3, NPN switched output max. max. 24 V/DC, 100 mA; switches to
minus potential (-). Suitable for control purposes (AUX)
13
Output 1 access control.
14
NPN switched output that switches to the minus potential (-) for 5 seconds
when a correct user code is entered. In a two-door system this can be
used to avoid both doors being opened at the same time (two code locks
required)
15
(-) Ground contact (GND/ground)
16
"DURESS" coercion contact - this contact switches to ground potential if
an incorrect code was entered 10 times during programming (71).
43

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis