» The installation must be carried out in accordance with the standards EN 12453 and EN 12445. The force setting of the
automatic module must be adapted to the gate. The actuator has a built-in safety device to prevent crushing injuries
which consists of a torque control. In any case it is necessary to adjust the torque control to the gate appropriately. To
minimize the risk of injury as far as possible, the force setting of the gate controller must be adapted to the gate as
follows.
» After hitting an obstacle the actuator will reverse direction.
» Level 4 is the factory programmed the force setting.
» The safety devices (EN 12978 standard) allow the securing of potentially hazardous areas and protect against mechani-
cal movement risks, such as crushing, dragging, and shearing injuries. During the programming of the force setting the
safety shut-off will not be active.
» Before attempting any work on the system, the electrical power supply should be disconnected. For the optimal utilization
of the radio control range, the radio receiver which is located in the controller can be mounted in an outdoor area.
» For each system it is recommended to use at least one light signal as well as a warning sign which should be connected
to the gate structure.
» Schellenberg disclaims any liability regarding the safety and smooth operation of the system, if components are used on
the system that were not supplied by Schellenberg.
» For the maintenance, only original parts made by Schellenberg should be used.
» The components that are part of the drive system are not allowed to be altered in any way.
» The installer must hand over all information to the operator of the system which concern the manual operation of the
system during emergencies as well as these installation instructions which were supplied with the product.
» Neither children nor adults are allowed to dwell in the immediate vicinity of the gate system during operation.
» The remote controls or other impulse transmitters must be kept out of reach of children to prevent accidental activation of
the actuator.
» A passage between the gate leafs is only allowed when the gate is fully open.
personnel to do so.
» Do not dispose of used batteries in the domestic trash! Appropriate collection-boxes are available in certain retailer
localities.
» All procedures that are not expressly provided in these instructions are not permitted.
» The commissioning of the gate system is prohibited until it has been determined that the gate system complies with the
provisions of all relevant applicable regulations and EU directives.