12 Volt:
Voltage supply 9 to 16 Volt DC. Connection is
performed to an existing central alarm station.
Please observe correct polarity "+" and "-"!
Tamper NC:
Anti-tamper contact. Connection is performed
to the corresponding contacts (NC = normally
closed) of an existing central alarm station.
Whenever the front cover is removed, the
contact opens, thus issuing a signal to the cen-
tral alarm station.
Relay NC:
Alarm
max. 28 Volt DC / 0.1A

Jumper Settings

LED ON/OFF:
ON = All LEDs are activated.
OFF = All LEDs are inactive.
Pulse:
Normal mode
Harsh mode

LEDs

LED 1 (green)
ON
LED 2 (yellow)
ON
LED 3 (red)
ON
24
output
switching
contact,
To this effect, refer to
Chapter "Walking Test".
upper sensor
lower sensor
Alarm was triggered
12 volts :
alimentation comprise entre 9 et 16 volts
c.c. Le détecteur de mouvement est rac-
cordé à une centrale d'alarme préalable-
ment installée. Veuillez respecter la polarité
"+" et "-" !
Contact NC "Tamper" : contact antisabotage. Le raccordement
s'effectue sur les contacts correspondants
(N.C. = normalement fermé) d'une centrale
d'alarme déjà en place. A chaque fois que
la plaque avant est retirée, le contact s'ouv-
re et transmet ainsi un signal à la centrale
d'alarme.
Relais NC :
Contact de commutation de commande de
sortie d'alarme,
max. 28 volts c.c. / 0,1 A
Réglage du pontage
DEL ON/OFF :
ON = allumée. Toutes les DEL sont activées
OFF = éteinte. Toutes les DEL sont désac-
tivées
Impulsions :
Fonctionnement normal
Fonctionnement harsh
de fonctionnement"
DEL
DEL 1 (verte)
ON / allumée
DEL 2 (jaune)
ON / allumée
DEL 3 (rouge)
ON / allumée
Voir pour cela
chapitre
"Essai
capteur supérieur
capteur inférieur
l'alarme a été déclenchée
37