Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data And Measuring Tolerances; Measurement Tolerances - Conrad F-100 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

ning, also use no sharp-edged tools, screwdrivers, metal brus-
hes or similar.

Technical data and measuring tolerances

Technical Data
Display . . . . . . . . . . . . . . . . .: 3 1/2-digit LCD display up to 1999
Max. measurement rate . . . .: 2 measurements per second
Max. voltage in the circuit
being measured . . . . . . . . . .: 600 Vrms in Overvoltage category II
Frequency range . . . . . . . . .: from 45 Hz to 100 Hz
Zero-setting . . . . . . . . . . . . .: automatic
Max. AC input current . . . . .: 600 A rms
Operating temperature . . . . .: 0°C to +50°C
relative humidity . . . . . . . . . .: 0 to 80 %, non-condensing
Temperature for guaranteed
accuracy . . . . . . . . . . . . . . . .: +23°C ±5 K max. at 80 % relative
Battery type . . . . . . . . . . . . .: 1.5 V type AAA or R03P
Battery life . . . . . . . . . . . . . .: approx. 1000 hours max. (with alka-
Max. clamp opening . . . . . . .: 25 mm diameter, max. contact dia-
Weight . . . . . . . . . . . . . . . . .: approx. 200 g (inc. battery)
Dimensions (L X W X H) . . . .: 187 x 50 x 29 mm
28
(LCD = liquid crystal display)
300 Vrms in Overvoltage category III
humidity, non-condensing. This ap-
plies up to 1 year after initial calibra-
tion.
line type)
meter: 25 mm, 25 mm

Measurement tolerances

Statement of accuracy in ±(% of reading + number of digits (=
dgt(s)). The accuracy applies for one (1) year at a temperature of
+23°C ±5°K, at a relative humidity of less than 80%, non-conden-
sing.
Operating Measuring
mode
range
Accuracy
AC
20 A
±(2%+5dgts) 0.01 A
current
200 A
±(2%+5dgts) 0.1
600 A
±(2%+5dgts) 1
Under no circumstances exceed the 600 AAC rms
maximum permissible input value. During this, in no
case may the voltage be higher than 600VAC rms in
Overvoltage Category II (domestic and commercial
areas) or 300 VAC rms in the Overvoltage Category
III (industrial areas)! The frequency of the AC values
may not exceed 100 Hz! Touch no circuits or circuit
components where voltages higher than 25 VAC
rms or 35 VDC can be present! Danger to life
Resolution
Frequency range
5 Hz to 100 Hz
A
45 Hz to 400 Hz
A
45 Hz to 400 Hz
29