Technical data and measuring tolerances

Technical Data
Display (Display) . . . . . . . . . . . .: 3 1/2-digit LC display up to
Max. measurement rate . . . . . . .: 2.5 measurements per second
Max. DC/AC measured current .: 1000 A or 1200 A max., for 60s
Max. conductor diameter : . . . . .57 mm round, or 70 x 18 mm as
current rail
Operating temperature . . . . . . .: 0°C to +50°C
Relative humidity . . . . . . . . . . . .: < 70 %, non-condensing
Storage temperature . . . . . . . . .: -20°C to +60°C (relative humidity
Temperature for
guaranteed accuracy . . . . . . . . .: +23°C ±5 K
Temperature coefficient . . . . . . .: 0.1 x given accuracy/K additio-
Battery type . . . . . . . . . . . . . . . .: 1 x 9 V battery, NEDA 1604 or
Battery life . . . . . . . . . . . . . . . . . .: approx. 300 hours (with alkaline
Max. operating altitude . . . . . . . .: 2000 m (6562 ft) above sea level
Contamination level . . . . . . . . . .:2 or Class 2
Weight . . . . . . . . . . . . . . . . . . . . .: approx. 502g (with battery)
Dimensions (L x W x H) . . . . . . .: approx. 277 x 102 x 49 mm
Downloaded from
www.Manualslib.com
manuals search engine
1999, 21 mm-high digits, with
automatic polarity indicator
max.
< 80%, non-condensing, battery
removed)
nal measurement error in the
ranges 0 to 18°C and 28°C to
50°C
JIS or IEC6LF222 or equivalent.
battery)
max.
45