10

Diode test

To test the diodes turn the rotary switch to position "Ω" and press
the "Mode" button twice to activate the "diode test" function.
Then connect the measuring contacts to the diode. The measured
value acquired for the forward voltage appears on the display.
If "O.L." appears on the display instead of a measured value, the
diode has either been tested in the reverse direction or is faulty.
If 0.0 V is measured, the diode is faulty or a short-circuit has occurred.
11

Capacitance measurement

To take a capacitance measurement, turn the rotary switch to position
"CAP" and press the "Mode" button three times to activate the
"Capacitance measurement" function. Then connect the measuring
contacts to the object to be tested. In the case of poled capacitors,
connect the positive pole to the red test prod.
26
EN
Red
Forward direction
Black
+
Black
Red
+