Technical Data

Voltage .................................. ~ 230 V , 50/60 Hz ........................
Nominal acceptance power ...... 2000 W .........................................
Gear ........................................ 1. .................... 2. ................................
-1
Speed (min
) ........................... 760 .................. 1570 ............................
Drilling diameter (Ø mm) .......... 62–162 ............ 10–62 ..........................
Drilling range ........................... Concrete
Weight ..................................... approx. 6,7 kg ...............................
Speed electronic ...................... yes ................................................
Tool fitting .................................................. outer 1.1/4" UNC, inner G 1/2"
Vibration ................................... 3,3 m/s
Drill bit types ............................ SPEED STAR DX, Duramant PRO, EUROLASER, DX-HSP
Class of protection ................ I ....................................................
Protection type ...................... IP 20 .............................................
Noise pressure level (L
Sound power level (L
The noise level during operation can exceed 85 dB (A). Wear hearing protection!
Measured values determined in accordance with EN 60745-1:2010.
3

Electric supply

Only connect to one-phase alternating current and to the mains voltage indicated on the power
rating plate.
3.1

Putting the PRCD switch into operation

Only suitable for AC current! Note the mains network voltage!
Perform the following test procedure on the PRCD switch before every putting into operation of
the device:
1. Connect the PRCD plug connector with the socket.
2. Press on RESET. The indicator switches to ORANGE (ON).
3. Pull the plug connector out of the socket. The display switches itself off.
4. Repeat 1. and 2.
5. Press on TEST. The orange indicator switches itself off.
6. Press on RESET to switch the device on (ORANGE).
These protective device protect against faults in the attached device, not against such
faults in the preceding plant.
14
RODIADRILL 160
max. 132 mm ................................
Masonry
max. 162 mm ................................
2
¦ K= 1,5 m/s
) ........ 91 dB (A) ¦ K
pA
) .......... 102 dB (A) ¦ K
WA
ENGLISH
RODIADRILL 200
~ 230 V , 50/60 Hz
2700 W
1. ............... 2. ................ 3.
600 ............ 1250 ........... 3200
102–250 .... 102–62 ....... 10–62
Concrete
max. 200 mm
Masonry
max. 250 mm
approx. 7,2 kg
yes
2
...................
4,5 m/s
I
IP 20
3 dB (A) ..............
92 dB (A) ¦ K
pA
3 dB (A) ............
103 dB (A) ¦ K
WA
2
2
¦ K= 1,5 m/s
3 dB (A)
pA
3 dB (A)
WA