5.4.2.2 In a new situation

To install an insert fire with a newly built chimney breast proceed as follows:
Ø
Determine the fire location. The dimensions are given in Annex 2, Fig. 1.
Ø
Place the fire on a floor with a sufficient load bearing capacity.
Ø
If applicable make a recess for an outside air connection (if applicable see section 9 'Appliance-specific
information').
Ø
Use non-combustible and heat-resistant material according to European fire classification A1 EN 13501-1 for the
plate on the floor, chimney breast (including the upper face), the material in the chimney breast and the back wall
against which the appliance is fitted. Plate material or stony materials can be used for this.
Ø
Leave a space of at least 10 mm between the fire and construction materials.
Ø
Be careful with the chimney breast plaster. Plaster beading makes the recess smaller.
Ø
Take account of the expansion of the fire. Keep the fire free of plasterwork.
Ø
If there is a flammable ceiling, place a fire-resistant plate with a 10 cm thick heat-insulating layer on top 30 cm
below the ceiling in the chimney breast.
Ø
If are there flammable materials (e.g. wooden floor parts/beams etc.) below or behind the fire, sufficient
non-combustible insulation material according to European fire classification A1 EN 13501-1 must be applied.
Comply with national regulations here.
Ø
If there is a flammable wall build a 10 cm-thick fire-safe wall.
Ø
Build the base or elevation with heat resistant material.
Ø
Place the steel plate supplied in the place for the fire. If applicable make a recess in it for the outside air
connection. Remove the fire door and disassemble the frame when it is supplied separately.
Ø
Remove the fire door and disassemble the frame when it is supplied separately (see section 9 'Appliance-specific
information').
Ø
Install the fire.
Ø
If applicable connect the outside air connection (see section 9 'Appliance-specific information').
Ø
If applicable connect the convection opening with the flexible aluminium pipe and ventilation elements.
Keeps these elements at least 30 cm away from the ceiling.
Ø
Use single-walled stainless steel flue pipes or stainless steel double-walled flexible pipes that at least meet the
requirements of standard EN 1856-2 T600.
Ø
The fire may never support the flue.
Ø
After the fire has been connected turn the adjustable legs with the Allen key supplied until the fire is in the
desired position. Make sure that the combustion air supply is not blocked when doing this.
Ø
Replace the restrictor cap for the outflow, fit the inner lining plates in reverse order and place the baffle plate
against the back wall and on the profiles (see section 9 'Appliance-specific information').
Ø
Use a torch or a thin screwdriver to check that the secondary ventilation holes in the back wall are directly facing
the recesses in the interior lining.
Ø
Replace the door and if applicable the frame around the fire (if applicable see section 9 'Appliance-specific
information').
Ø
Lay a fire-resistant floor plate for the fire if the floor is flammable. The floor plate of non-flammable
material must extend at least 300 mm away from the fire and be at least 300 mm wider than the fire.