Herunterladen Inhalt Inhalt Diese Seite drucken

Panasonic WH-SHF09F3E5 Bedienungsanleitung Seite 7

Luft/wasser-wärmepumpe
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 44
Operation/settings to be done only by the authorised dealer/specialist.
Dealer
Operation/settings to be done by the authorised dealer/specialist or user.
User
Booster Heater
9
To activate or deactivate the water tank's booster heater.
Note: If NO is selected, menu 10 is skipped.
Booster Heater Delay Timer
10
To delay time for the booster heater to activate while the system is heating up
the water tank.
• Do not use the system during sterilisation in order to prevent scalding with hot water, or overheating of shower.
• Ask an authorised dealer to determine the level of sterilisation function field settings according to the local laws and
regulations.
Sterilisation
11
To sterilise the water tank, if required.
Note: If NO is selected, menus 12 to 14 are skipped.
Sterilisation Day & Time
12
To set timer for sterilisation.
(Only once a week. Operates even under a standby condition)
Sterilisation Temperature
13
To set the temperature of sterilisation.
Continuation of Sterilisation
14
To maintain heating temperature in order to complete the sterilisation.
Base Pan Heater
15
To select whether or not to connect to the optional base pan heater.
Note: If NO is selected, menu 16 is skipped.
Base Pan Heater type
16
Type A - The base pan heater activates only during deice operation.
Type B - The base pan heater activates when outdoor ambient temperature is
5 °C or lower.
Dry Concrete
17
During construction to dry the concrete under a preset temperature.
Do not use this menu for any other purposes and in period other than during
construction (Refer to Information page).
User
Control panel preparation
1 Press
.
2 Press
or
to set the current day.
3 Press
to confirm.
4 Repeat steps 2 and 3 to set the current time.
Note:
• The current day and time need to be set in cases below:
- When the power is turned on for the first time.
- A long time has elapsed since the power was turned on the
last time.
• The current time that has been set will be the standard time for
all the timer operations.
YES
20 minutes ~
1 hour 35 minutes
YES
Monday ~
Sunday
0:00 ~ 23:50
40 °C ~ 75 °C
5 minutes ~
1 hour
YES
A
1 day ~ 99 days
Caution Indicator (Tank Temperature above 60 °C)
NO
NO
NO
B
7

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading